Your browser doesn't support javascript.
loading
Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications.
Ficek, Mateusz; Cieslik, Mateusz; Janik, Monika; Brodowski, Mateusz; Sawczak, Miroslaw; Bogdanowicz, Robert; Ryl, Jacek.
Afiliação
  • Ficek M; Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdansk, Poland.
  • Cieslik M; Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdansk, Poland.
  • Janik M; Department of Analytical Chemistry, University of Gdansk, Wita Stwosza 63, 80-308, Gdansk, Poland.
  • Brodowski M; Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdansk, Poland.
  • Sawczak M; Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662, Warsaw, Poland.
  • Bogdanowicz R; Gdansk University of Technology, Narutowicza 11/12, 80-233, Gdansk, Poland.
  • Ryl J; Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Fiszera 14, Gdansk, Poland.
Mikrochim Acta ; 190(10): 410, 2023 09 22.
Article em En | MEDLINE | ID: mdl-37736868
ABSTRACT
This paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials' architecture and the receptor immobilisation procedures. The study presents a two-step modification process involving the electroreduction of diazonium salt at the BDDPE and the immobilisation of antibodies using zero-length cross-linkers for a selective impedimetric biosensor of Haemophilus influenzae (Hi). The incorporation of diamond nanosheets into BDDPE leads to enhanced charge transfer and electrochemical behaviour, demonstrating greatly improved electrochemically active surface area compared with unmodified screen-printed electrodes (by 44% and 10% on average for [Ru(NH3)6]Cl2 and K3[Fe(CN)6], respectively). The presented sensing system shows high specificity towards protein D in Hi bacteria, as confirmed by negative controls against potential interference from other pathogens, with an estimated tolerance limit for interference under 12%. The Hi limit of detection by electrochemical impedance spectroscopy was 1 CFU/mL (measured at - 0.13 V vs BDDPE pseudo-reference), which was achieved in under 10 min, including 5 min sample incubation in the presence of the analyte.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carbono / Diamante Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carbono / Diamante Idioma: En Ano de publicação: 2023 Tipo de documento: Article