ABSTRACT
Background and Objectives:
Polymer-free ultrathin strut sirolimus- and probucol-eluting stents (PF-SES) are recognized as safe and effective in diverse patient populations, although the implications of post-dilation during stent implantation remain underexamined. Materials andMethods:
In this study, patients implanted with PF-SES at Gachon University Gil Medical Center between December 2014 and February 2018 were evaluated. Major adverse cardiovascular events (MACE), encompassing nonfatal myocardial infarction (MI), nonfatal stroke, and cardiovascular death were identified as primary outcomes, with secondary outcomes including target vessel revascularization (TVR), target lesion revascularization (TLR), and in-stent restenosis (ISR).Results:
Of the 384 initial patients, 299 were considered eligible for analysis. The groups, delineated by those undergoing post-dilation (143 patients) and those not (156 patients), exhibited comparable rates of primary outcomes [hazard ratio (HR), 2.17; 95% confidence interval (CI), 0.40 to 11.87; p = 0.37]. The outcomes remained consistent irrespective of the post-dilation status and were similarly unaffected in multivariate analyses (HR, 2.90; 95% CI, 0.52 to 16.34; p = 0.227).Conclusions:
These results suggest that the clinical outcomes of patients with post-dilation were similar to that of those without post-dilation in those with the polymer-free sirolimus- and probucol-eluting stents.