Your browser doesn't support javascript.
loading
Automated measurements of interscrew angles in vertebral body tethering patients with deep learning.
Mulford, Kellen L; Regan, Christina; Nolte, Charles P; Pinter, Zachariah W; Milbrandt, Todd A; Larson, A Noelle.
Afiliação
  • Mulford KL; Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA.
  • Regan C; Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA.
  • Nolte CP; Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA.
  • Pinter ZW; Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA.
  • Milbrandt TA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA.
  • Larson AN; Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, 200 1st St SW, Rochester, MN 55905, USA. Electronic address: Larson.Noelle@mayo.edu.
Spine J ; 24(2): 333-339, 2024 02.
Article em En | MEDLINE | ID: mdl-37774982
ABSTRACT
BACKGROUND CONTEXT Vertebral body tethering is the most popular nonfusion treatment for adolescent idiopathic scoliosis. The effect of the tether cord on the spine can be segmentally assessed by comparing the angle between two adjacent screws (interscrew angle) over time. Tether breakage has historically been assessed radiographically by a change in adjacent interscrew angle by greater than 5° between two sets of imaging. A threshold for growth modulation has not yet been established in the literature. These angle measurements are time consuming and prone to interobserver variability.

PURPOSE:

The purpose of this study was to develop an automated deep learning algorithm for measuring the interscrew angle following VBT surgery. STUDY DESIGN/

SETTING:

Single institution analysis of medical images. PATIENT SAMPLE We analyzed 229 standing or bending AP or PA radiographs from 100 patients who had undergone VBT at our institution. OUTCOME

MEASURES:

Physiologic

Measures:

An image processing algorithm was used to measure interscrew angles.

METHODS:

A total of 229 standing or bending AP or PA radiographs from 100 VBT patients with vertebral body tethers were identified. Vertebral body screws were segmented by hand for all images and interscrew angles measured manually for 60 of the included images. A U-Net deep learning model was developed to automatically segment the vertebral body screws. Screw label maps were used to develop and tune an image processing algorithm which measures interscrew angles. Finally, the completed model and algorithm pipeline was tested on a 30-image test set. Dice score and absolute error were used to measure performance.

RESULTS:

Inter- and Intra-rater reliability for manual angle measurements were assessed with ICC and were both 0.99. The segmentation model Dice score against manually segmented ground truth across the 30-image test set was 0.96. The average interscrew angle absolute error between the algorithm and manually measured ground truth was 0.66° and ranged from 0° to 2.67° in non-overlapping screws (N=206). The primary modes of failure for the model were overlapping screws on a right thoracic/left lumbar construct with two screws in one vertebra and overexposed images. An algorithm step which determines whether an overlapping screw was present correctly identified all overlapping screws, with no false positives.

CONCLUSION:

We developed and validated an algorithm which measures interscrew angles for radiographs of vertebral body tether patients with an accuracy of within 1° for the majority of interscrew angles. The algorithm can process five images per second on a standard computer, leading to substantial time savings. This algorithm may be used for rapid processing of large radiographic databases of tether patients and could enable more rigorous definitions of growth modulation and cord breakage to be established.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escoliose / Aprendizado Profundo Tipo de estudo: Guideline / Prognostic_studies Limite: Adolescent / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escoliose / Aprendizado Profundo Tipo de estudo: Guideline / Prognostic_studies Limite: Adolescent / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article