Your browser doesn't support javascript.
loading
Multidimensional compressed sensing to advance 23 Na multi-quantum coherences MRI.
Licht, Christian; Reichert, Simon; Guye, Maxime; Schad, Lothar R; Rapacchi, Stanislas.
Afiliação
  • Licht C; Computer Assisted Clinical Medicine, Medical Faculty Mannhein, Heidelberg University, Mannheim, Germany.
  • Reichert S; Mannheim Institute for Intelligent System in Medicine, Medical Faculty Mannheim, Mannheim, Germany.
  • Guye M; Computer Assisted Clinical Medicine, Medical Faculty Mannhein, Heidelberg University, Mannheim, Germany.
  • Schad LR; Mannheim Institute for Intelligent System in Medicine, Medical Faculty Mannheim, Mannheim, Germany.
  • Rapacchi S; Aix-Marseille Univ, CNRS, CRMBM, Marseille, France.
Magn Reson Med ; 91(3): 926-941, 2024 Mar.
Article em En | MEDLINE | ID: mdl-37881829
PURPOSE: Sodium (23 Na) multi-quantum coherences (MQC) MRI was accelerated using three-dimensional (3D) and a dedicated five-dimensional (5D) compressed sensing (CS) framework for simultaneous Cartesian single (SQ) and triple quantum (TQ) sodium imaging of in vivo human brain at 3.0 and 7.0 T. THEORY AND METHODS: 3D 23 Na MQC MRI requires multi-echo paired with phase-cycling and exhibits thus a multidimensional space. A joint reconstruction framework to exploit the sparsity in all imaging dimensions by extending the conventional 3D CS framework to 5D was developed. 3D MQC images of simulated brain, phantom and healthy brain volunteers obtained from 3.0 T and 7.0 T were retrospectively and prospectively undersampled. Performance of the CS models were analyzed by means of structural similarity index (SSIM), root mean squared error (RMSE), signal-to-noise ratio (SNR) and signal quantification of tissue sodium concentration and TQ/SQ ratio. RESULTS: It was shown that an acceleration of three-fold, leading to less than 2 × 10 $$ 2\times 10 $$ min of scan time with a resolution of 8 × 8 × 20 mm 3 $$ 8\times 8\times 20\;{\mathrm{mm}}^3 $$ at 3.0 T, are possible. 5D CS improved SSIM by 3%, 5%, 1% and reduced RMSE by 50%, 30%, 8% for in vivo SQ, TQ, and TQ/SQ ratio maps, respectively. Furthermore, for the first time prospective undersampling enabled unprecedented high resolution from 8 × 8 × 20 mm 3 $$ 8\times 8\times 20\;{\mathrm{mm}}^3 $$ to 6 × 6 × 10 mm 3 $$ 6\times 6\times 10\;{\mathrm{mm}}^3 $$ MQC images of in vivo human brain at 7.0 T without extending acquisition time. CONCLUSION: 5D CS proved to allow up to three-fold acceleration retrospectively on 3.0 T data. 2-fold acceleration was demonstrated prospectively at 7.0 T to reach higher spatial resolution of 23 Na MQC MRI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imageamento Tridimensional Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imageamento Tridimensional Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article