Your browser doesn't support javascript.
loading
Within- and between-day reliability and repeatability of neuromuscular function assessment in females and males.
Dutra, Yago Medeiros; Lopes, João Pedro Fialho; Murias, Juan M; Zagatto, Alessandro Moura.
Afiliação
  • Dutra YM; Department of Physical Education, Laboratory of Physiology and Sport Performance (LAFIDE), School of Sciences, São Paulo State University (UNESP), Bauru, Brazil.
  • Lopes JPF; Department of Physical Education, Laboratory of Physiology and Sport Performance (LAFIDE), School of Sciences, São Paulo State University (UNESP), Bauru, Brazil.
  • Murias JM; College of Health and Life Sciences, Hamad Bin Khalifa University, Doha, Qatar.
  • Zagatto AM; Department of Physical Education, Laboratory of Physiology and Sport Performance (LAFIDE), School of Sciences, São Paulo State University (UNESP), Bauru, Brazil.
J Appl Physiol (1985) ; 135(6): 1372-1383, 2023 12 01.
Article em En | MEDLINE | ID: mdl-37916269
ABSTRACT
The study evaluated the reliability and repeatability of the force and surface electromyography activity (EMG) outcomes obtained through voluntary and electrically evoked contractions of knee extensors in females (n = 18) and males (n = 20) and compared these data between sexes. Maximal isometric voluntary contractions (iMVCs) of knee extensors associated with electrical stimulation of the femoral nerve were performed over 4 days (48-h interval), with the first day involving familiarization procedures, the second involving three trials (1-h interval), and the third and fourth involving just one trial. The intraclass correlation coefficient (ICC), coefficient of variation (CV), and repeatability of outcomes from within- and between-day trials were determined for each sex. Females presented lower maximal voluntary force during iMVC (iMVCForce) and associated vastus lateralis EMG activity (root mean square, RMSVL), force evoked by potentiated doublet high-frequency (Db100Force) and single stimuli (Qtw), and M-wave amplitude than males (P ≤ 0.01, partial eta squared ≥0.94). Voluntary activation (VA) and RMSVL/M-wave amplitude did not differ between sexes. iMVCForce, VA, Db100Force, Qtw, and M-wave amplitude were the most reliable outcomes in within-day trials, with similar results between sexes (ICC > 0.62; CV < 6.4%; repeatability 12.2%-22.6%). When investigating between-day trials, the iMVCForce, VA, Db100Force, and Qtw were the most reliable (ICC > 0.66; CV < 7.5%; repeatability 13.2%-33.45%) with similar results between sexes. In conclusion, females presented lower iMVCForce and evoked response than males. Although reliability and repeatability statistics vary between trials, data (e.g., from EMG or force signal), and sexes, most of the outcomes obtained through this technique are reliable in females and males.NEW & NOTEWORTHY Although reliability and repeatability of knee extensors vary according to the type of neuromuscular function outcome (e.g., from force or EMG responses), the trial intervals (i.e., hours or days), and the sex of the participant, most force and EMG outcomes obtained through these neuromuscular assessment protocols present ICC > 0.75, very good CV (<10%), and repeatability <25% in within- and between-day trials in both sexes.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contração Isométrica / Joelho Limite: Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contração Isométrica / Joelho Limite: Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article