Your browser doesn't support javascript.
loading
Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease.
Atzori, Sebastiana M; Pasha, Yasmin; Maurice, James B; Taylor-Robinson, Simon D; Campbell, Louise; Lim, Adrian K P.
Afiliação
  • Atzori SM; Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; Department of Medicine, Sassari University Hospital, Via Enrico de Nicola, Sassari 07100, Italy. Electronic address: sebastiana_atzori@aouss.it.
  • Pasha Y; Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom.
  • Maurice JB; Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; UCL Institute for Liver and Digestive Health, Royal Free Hospital Campus, London, Rowland Hill Street, NW3 2QG, United Kingdom.
  • Taylor-Robinson SD; Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom.
  • Campbell L; Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; Office of the Clinical Director, Tawazun Health, 23 Harley Street, London W1G 9QN, United Kingdom.
  • Lim AKP; Imaging Department, Charing Cross Hospital, Imperial College Healthcare NHS Trust, Fulham Palace Road, London W6 8RF, United Kingdom.
Dig Liver Dis ; 56(3): 484-494, 2024 Mar.
Article em En | MEDLINE | ID: mdl-37968144
ABSTRACT

BACKGROUND:

Most ultrasound-based methods for assessing liver fibrosis still need further validation with liver biopsy used as gold standard to assess their accuracy.

AIMS:

To assess accuracy of three shear wave elastography (SWE)

methods:

1) Philips Elast Point Quantification (ElastPQTM), 2) Siemens Virtual TouchTM Quantification (VTQ) acoustic radiation force impulse (ARFI), and 3) transient elastography (TE) measured by Echosens FibroscanTM.

METHODS:

160 patients underwent liver stiffness measurements (LSM) with three SWE methods immediately prior to liver biopsy.

RESULTS:

The number of LSM required for reliable studies could be reduced to 6 for ElastPQ and to 7 for VTQ from standard recommendations of 10. Significant fibrosis and interquartile range/median (IQR/M)> 30 were independent predictors for lower reliability for detection of liver fibrosis. Ordinal logistic regression corrected for age showed that there was a significant interaction between steatosis (p = 0.008) and lobular inflammation (p = 0.04) and VTQ (ARFI) and between lobular inflammation and TE (p = 0.006).

CONCLUSIONS:

We showed variations in SWE measurements using different ARFI technologies. TE and ElastPQ achieved good diagnostic performance, whereas VTQ showed lower diagnostic accuracy. The number of measurements required for reliable studies can be reduced to 6 for ElastPQ and to 7 for VTQ, which have important clinical implications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade / Hepatopatias Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade / Hepatopatias Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article