Your browser doesn't support javascript.
loading
Recovery and safety with prolonged high-frequency jet ventilation for catheter ablation of atrial fibrillation: A hospital registry study from a New England healthcare network.
Munoz-Acuna, Ricardo; Tartler, Tim M; Azizi, Basit A; Suleiman, Aiman; Ahrens, Elena; Wachtendorf, Luca J; Linhardt, Felix C; Chen, Guanqing; Tung, Patricia; Waks, Jonathan W; Schaefer, Maximilian S; Sehgal, Sankalp.
Afiliação
  • Munoz-Acuna R; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Tartler TM; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Azizi BA; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Suleiman A; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Ahrens E; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Wachtendorf LJ; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Linhardt FC; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Chen G; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 375 Longwood Avenue, Boston, MA 02215, United States of America. Electronic address: gchen7@bidmc.harvard.edu.
  • Tung P; Harvard-Thorndike Electrophysiology Institute, Division of Cardiovascular Medicine, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America. Electronic address: ptung@bidmc.harvard.edu.
  • Waks JW; Harvard-Thorndike Electrophysiology Institute, Division of Cardiovascular Medicine, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America. Electronic address: jwaks@bidmc.harvard.edu.
  • Schaefer MS; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America; Center for Anesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Center, Harvard Medical School, 3
  • Sehgal S; Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States of America. Electronic address: ssehgal@bidmc.harvard.edu.
J Clin Anesth ; 93: 111324, 2024 05.
Article em En | MEDLINE | ID: mdl-38000222
ABSTRACT
STUDY

OBJECTIVE:

To investigate post-procedural recovery as well as peri-procedural respiratory and hemodynamic safety parameters with prolonged use of high-frequency jet ventilation (HFJV) versus conventional ventilation in patients undergoing catheter ablation for atrial fibrillation.

DESIGN:

Hospital registry study.

SETTING:

Tertiary academic teaching hospital in New England. PATIENTS 1822 patients aged 18 years and older undergoing catheter ablation between January 2013 and June 2020.

INTERVENTIONS:

HFJV versus conventional mechanical ventilation. MEASUREMENTS The primary outcome was post-anesthesia care unit (PACU) length of stay. In secondary analyses we assessed the effect of HFJV on intra-procedural hypoxemia, defined as the occurrence of peripheral hemoglobin oxygen saturation (SpO2) <90%, post-procedural respiratory complications (PRC) as well as intra-procedural hypocarbia and hypotension. Multivariable negative binomial and logistic regression analyses, adjusted for patient and procedural characteristics, were applied. MAIN

RESULTS:

1157 patients (63%) received HFJV for a median (interquartile range [IQR]) duration of 307 (253-360) minutes. The median (IQR) length of stay in the PACU was 244 (172-370) minutes in patients who underwent ablation with conventional mechanical ventilation and 226 (163-361) minutes in patients receiving HFJV. In adjusted analyses, patients undergoing HFJV had a longer PACU length of stay (adjusted absolute difference 37.7 min; 95% confidence interval [CI] 9.7-65.8; p = 0.008). There was a higher risk of intra-procedural hypocarbia (adjusted odds ratio [ORadj] 5.90; 95%CI 2.63-13.23; p < 0.001) and hypotension (ORadj 1.88; 95%CI 1.31-2.72; p = 0.001) in patients undergoing HFJV. No association was found between the use of HFJV and intra-procedural hypoxemia or PRC (p = 0.51, and p = 0.97, respectively).

CONCLUSION:

After confounder adjustment, HFJV for catheter ablation procedures for treatment of atrial fibrillation was associated with a longer length of stay in the PACU. It was further associated with an increased risk of intra-procedural abnormalities including abnormal carbon dioxide homeostasis, as well as intra-procedural arterial hypotension.