Your browser doesn't support javascript.
loading
Inactivation of Bacteria in Water by Ferrate(VI): Efficiency and Mechanisms.
Mao, Yu; Chen, Zhuo; Lu, Yun; Cao, Ke-Fan; Wu, Yinhu; Hu, Hong-Ying.
Afiliação
  • Mao Y; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, P. R
  • Chen Z; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, P. R
  • Lu Y; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, P. R
  • Cao KF; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, P. R
  • Wu Y; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, P. R
  • Hu HY; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing 100084, P. R
Environ Sci Technol ; 57(49): 20893-20904, 2023 Dec 12.
Article em En | MEDLINE | ID: mdl-38032700
ABSTRACT
Ferrate (Fe(VI)) is an emerging green disinfectant and has received increasing attention nowadays. This study conducted systematic analyses of Fe(VI) disinfection on six typical bacteria in different water matrices. The results showed that Fe(VI) was more effective in inactivating Gram-negative (G-) bacteria than Gram-positive (G+) bacteria, and the disinfection performance of Fe(VI) was better in a phosphate buffer than that in a borate buffer and secondary effluent. The inactivation rate constants of G- bacteria were significantly higher than those of G+ bacteria. The cell membrane damage of G- bacteria was also more severe than that of G+ bacteria after Fe(VI) treatment. The cell wall structure, especially cell wall thickness, might account for the difference of the inactivation efficiency between G- bacteria and G+ bacteria. Moreover, it is revealed that Fe(VI) primarily reacted with proteins rather than other biological molecules (i.e., phospholipids, peptidoglycan, and lipopolysaccharide). This was further evidenced by the reduction of bacterial autofluorescence due to the destruction of bacterial proteins during Fe(VI) inactivation. Overall, this study advances the understanding of Fe(VI) disinfection mechanisms and provides valuable information for the Fe(VI) application in water disinfection.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Purificação da Água Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Purificação da Água Idioma: En Ano de publicação: 2023 Tipo de documento: Article