Your browser doesn't support javascript.
loading
Measurement of CO2 Isotopologue Ratios Using a Hollow Waveguide-Based Mid-Infrared Dispersion Spectrometer.
Zhang, Haojie; Wu, Tao; Wu, Qiang; Chen, Weidong; Ye, Chenwen; Wang, Mengyu; He, Xingdao.
Afiliação
  • Zhang H; Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China.
  • Wu T; Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China.
  • Wu Q; Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China.
  • Chen W; Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, U.K.
  • Ye C; Laboratoire de Physicochimie de l'Atmosphère,Université du Littoral Côte d'Opale, 189A Av. Maurice Schumann, Dunkerque 59140, France.
  • Wang M; Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China.
  • He X; Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China.
Anal Chem ; 95(50): 18479-18486, 2023 Dec 19.
Article em En | MEDLINE | ID: mdl-38054623
We demonstrate for the first time the measurement of CO2 isotope ratios (13C/12C and 18O/16O) in a hollow waveguide (HWG) fiber using a mid-infrared heterodyne phase-sensitive dispersion spectrometer (HPSDS). A 4.329 µm interband cascade laser is used to target the absorption lines of three CO2 isotopes (13C16O2, 18O12C16O, and 12C16O2) in a 1 m long and 1 mm inner diameter HWG fiber. The detection limits are 0.29 ppm, 65.78 ppb, and 14.65 ppm with an integration time of 218 s for 13C16O2, 18O12C16O, and 12C16O2, respectively, at a modulation frequency of 160 MHz and a pressure of 230 mbar. The measurement precisions of δ13C and δ18O are 0.89 and 0.88 ‰, respectively, corresponding to an integration time of 167 s. An experimental comparison between a HPSDS and a built wavelength modulation system with second-harmonic detection (WMS-2f) is conducted. The results show that compared to the WMS-2f, the developed HPSDS exhibits a greater linear dynamic range and excellent long-term stability. This work aims to demonstrate a detection technique of CO2 isotope dispersion spectroscopy with a large dynamic range for relevant applications focusing on samples with high concentrations of CO2 (% volume fraction), such as respiratory analysis in medical diagnostics.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article