Your browser doesn't support javascript.
loading
Placement of Temporary Left Ventricular Assist Device Using Monitored Anesthesia Care and Regional Anesthesia.
DePaolo, John; Iyengar, Amit; Cohen, Samuel; Kelly, John J; Spelde, Audrey E; Wald, Joyce; Mackay, Emily J; Ibrahim, Michael; Usman, Asad A; Cevasco, Marisa.
Afiliação
  • DePaolo J; Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Iyengar A; Division of Cardiovascular Surgery, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Cohen S; Department of Anesthesiology and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Kelly JJ; Division of Cardiovascular Surgery, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Spelde AE; Department of Anesthesiology and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Wald J; Division of Cardiovascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Mackay EJ; Department of Anesthesiology and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Ibrahim M; Division of Cardiovascular Surgery, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Usman AA; Department of Anesthesiology and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Cevasco M; Division of Cardiovascular Surgery, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
JACC Case Rep ; 26: 102067, 2023 Nov 15.
Article em En | MEDLINE | ID: mdl-38094172
ABSTRACT
Patients with advanced cardiogenic shock requiring mechanical circulatory support are uniquely susceptible to clinical deterioration. Limiting physiologic perturbations via avoidance of general anesthesia and endotracheal intubation by awake Impella 5.5 placement is safe and may represent a novel strategy in mechanical circulatory support initiation among patients in cardiogenic shock. (Level of Difficulty Intermediate.).
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article