Numerical study on the hydrodynamic performance and internal flow of an axial-flow pump with various inlet flow angles.
Son, Yong-Jin; Kim, Yong-In; Yang, Hyeon-Mo; Lee, Kyoung-Yong; Yoon, Joon Yong; Choi, Young-Seok.
Afiliação
  • Son YJ; Carbon Neutral Technology R&D Department, Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology, 89 Yangdaegiro-gil, Ipjang-Myeon, Seobuk-gu, Cheonan-si, 31056, Chungcheongnam-do, Republic of Korea.
  • Kim YI; Department of Mechanical Engineering, Hanyang University, Seoul, 133-791, Republic of Korea.
  • Yang HM; Aerospace Technology Research Institute-3rd Directorate Team 1, Agency for Defense Development, Yuseong, P.O. Box 35, Daejeon, 34186, Republic of Korea.
  • Lee KY; Carbon Neutral Technology R&D Department, Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology, 89 Yangdaegiro-gil, Ipjang-Myeon, Seobuk-gu, Cheonan-si, 31056, Chungcheongnam-do, Republic of Korea.
  • Yoon JY; Mechanical Engineering, Korea University of Technology and Education, 1600, Chungjeol-ro, Byeongcheon-Myeon, Dongnam-gu, Cheonan-si, Chungcheongnam-do, Republic of Korea.
  • Choi YS; Carbon Neutral Technology R&D Department, Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology, 89 Yangdaegiro-gil, Ipjang-Myeon, Seobuk-gu, Cheonan-si, 31056, Chungcheongnam-do, Republic of Korea.
Sci Rep ; 13(1): 22303, 2023 Dec 15.
Article em En | MEDLINE | ID: mdl-38102231
ABSTRACT
In this study, numerical simulation was employed to predict the performance and internal flow characteristics of the inlet of an axial-flow pump by assigning an absolute flow angle to the inlet guide vane (IGV) trailing-edge flow. Further, the finite volume method based on the three-dimensional Reynolds-averaged Navier-Stokes equations was employed to discretize the governing equations. The shear stress transport model was used as the turbulence model, and an appropriate number of nodes were selected for the hexahedral grid system through a grid-dependency test. The performance curve and changes in the internal flow field were investigated based on the variation in the flow angle at the inlet of the axial-flow pump. These results can be used to establish an efficient operational plan by adjusting the IGV angle of IGV when installing a variable IGV for an axial-flow pump.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article