A reliable external calibration method for reaction monitoring with benchtop NMR.
Maschmeyer, Tristan; Conklin, Breanna; Malig, Thomas C; Russell, David J; Kurita, Kenji L; Hein, Jason E; Napolitano, José G.
Afiliação
  • Maschmeyer T; Synthetic Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA.
  • Conklin B; Department of Chemistry, The University of British Columbia, Vancouver, British Columbia, Canada.
  • Malig TC; Synthetic Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA.
  • Russell DJ; Synthetic Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA.
  • Kurita KL; Synthetic Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA.
  • Hein JE; Synthetic Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA.
  • Napolitano JG; Department of Chemistry, The University of British Columbia, Vancouver, British Columbia, Canada.
Magn Reson Chem ; 62(3): 169-178, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38116902
ABSTRACT
Nuclear magnetic resonance (NMR) spectroscopy is a powerful analytical technique with the ability to acquire both quantitative and structurally insightful data for multiple components in a test sample. This makes NMR spectroscopy a desirable tool to understand, monitor, and optimize chemical transformations. While quantitative NMR (qNMR) approaches relying on internal standards are well-established, using an absolute external calibration scheme is beneficial for reaction monitoring as resonance overlap complications from an added reference material to the sample can be avoided. Particularly, this type of qNMR technique is of interest with benchtop NMR spectrometers as the likelihood of resonance overlap is only enhanced with the lower magnetic field strengths of the used permanent magnets. The included study describes a simple yet robust methodology to determine concentration conversion factors for NMR systems using single- and multi-analyte linear regression models. This approach is leveraged to investigate a pharmaceutically relevant amide coupling batch reaction. An on-line stopped-flow (i.e., interrupted-flow or paused-flow) benchtop NMR system was used to monitor both the 1,1'-carbonyldiimidazole (CDI) promoted acid activation and the amide coupling. The results highlight how quantitative measurements in benchtop NMR systems can provide valuable information and enable analysts to make decisions in real time.