Your browser doesn't support javascript.
loading
Enzyme Reaction-Assisted Programmable Transcriptional Switches for Bioactive Molecule Detection.
Tang, Xiaochen; Chen, Tianshu; Ma, Yonggeng; Mao, Changqing; Hu, Song; Zhang, Runchi; Yan, Yilin; Pan, Qiuhui; Feng, Chang; Zhu, Xiaoli.
Afiliação
  • Tang X; Department of Clinical Laboratory Medicine, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, P. R. China.
  • Chen T; Faculty of Medical Laboratory Science, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, P. R. China.
  • Ma Y; Shanghai Key Laboratory of Clinical Molecular Diagnostics for Pediatrics, Shanghai 200127, P. R. China.
  • Mao C; Department of Clinical Laboratory Medicine, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, P. R. China.
  • Hu S; Shanghai Key Laboratory of Clinical Molecular Diagnostics for Pediatrics, Shanghai 200127, P. R. China.
  • Zhang R; Center for Molecular Recognition and Biosensing, Shanghai Engineering Research Center of Organ Repair, School of Life Sciences, Shanghai University, Shanghai 200444, P. R. China.
  • Yan Y; Center for Molecular Recognition and Biosensing, Shanghai Engineering Research Center of Organ Repair, School of Life Sciences, Shanghai University, Shanghai 200444, P. R. China.
  • Pan Q; Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital of Tongji University, Shanghai 200072, P. R. China.
  • Feng C; Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital of Tongji University, Shanghai 200072, P. R. China.
  • Zhu X; Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital of Tongji University, Shanghai 200072, P. R. China.
Anal Chem ; 96(1): 331-338, 2024 01 09.
Article em En | MEDLINE | ID: mdl-38127443
ABSTRACT
Bioactive molecules are highly worthwhile to recognize and explore the latent pathogenic mechanism. Conventional methods for bioactive molecule detection, including mass spectrometry and fluorescent probe imaging, are limited due to the complex processing and signal interference. Here, we designed enzyme-reaction-assisted programmable transcriptional switches for the detection of bioactive molecules. The approach is based on the use of programmable enzyme site-specific cleavage-assisted DNA triplex-based conformational switches that, upon responding to bioactive molecules, can trigger the transcription of fluorescent light-up aptamers. Thanks to the programmable nature of the sensing platform, the method can be adapted to different bioactive molecules, and we demonstrated the enzyme-small molecule catalytic reaction combination of myeloperoxidase (MPO)-hydrogen peroxide (H2O2) as a model that transcriptional switches was capable of detecting H2O2 and possessed the specificity and anti-interference ability in vitro. Furthermore, we successfully applied the switches into cells to observe the detection feasibility in vivo, and dynamically monitored changes of H2O2 in cellular oxidative stress levels. Therefore, we attempt to amalgamate the advantages of enzyme reaction with the pluripotency of programmable transcriptional switches, which can take both fields a step further, which may promote the research of biostimuli and the construction of DNA molecular devices.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: DNA / Peróxido de Hidrogênio Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: DNA / Peróxido de Hidrogênio Idioma: En Ano de publicação: 2024 Tipo de documento: Article