Your browser doesn't support javascript.
loading
A High-Throughput Experimental Approach to Screening Gas Sorption by Liquids and Solids.
Young, J Mark; McCalmont, Sam H; Fourmentin, Sophie; Manesiotis, Panagiotis; Holbrey, John D; Moura, Leila.
Afiliação
  • Young JM; QUILL Research Centre, Queen's University Belfast, School of Chemistry and Chemical Engineering, David Keir Building, 39-123 Stranmillis Road, Belfast, BT9 5AG, United Kingdom.
  • McCalmont SH; QUILL Research Centre, Queen's University Belfast, School of Chemistry and Chemical Engineering, David Keir Building, 39-123 Stranmillis Road, Belfast, BT9 5AG, United Kingdom.
  • Fourmentin S; Unité de Chimie Environnementale et Interactions sur le Vivant (UCEIV), EA 4492, Condorcet FR CNRS 3417, Université du Littoral-Côte d'Opale, 59140 Dunkerque, France.
  • Manesiotis P; Queen's University Belfast, School of Chemistry and Chemical Engineering, David Keir Building, 39-123 Stranmillis Road, Belfast, BT9 5AG, United Kingdom.
  • Holbrey JD; QUILL Research Centre, Queen's University Belfast, School of Chemistry and Chemical Engineering, David Keir Building, 39-123 Stranmillis Road, Belfast, BT9 5AG, United Kingdom.
  • Moura L; QUILL Research Centre, Queen's University Belfast, School of Chemistry and Chemical Engineering, David Keir Building, 39-123 Stranmillis Road, Belfast, BT9 5AG, United Kingdom.
ACS Sustain Chem Eng ; 11(50): 17787-17796, 2023 Dec 18.
Article em En | MEDLINE | ID: mdl-38130843
ABSTRACT
High-precision measurement of gas uptake from single or mixed feeds in solid and liquid sorbents traditionally requires time-consuming experimental procedures and/or complex and costly equipment. A simple and cost-effective headspace gas chromatography (HS-GC) approach for the fast, universal experimental screening of sorbents for gas uptake and/or determination of their real gas separation selectivity has been developed and is demonstrated for pressures up to 2500 mbar and temperatures above 30 °C. This method allows screening of solids and both volatile and nonvolatile liquid materials, physisorbents, and chemisorbents using both single and mixed permanent gases that can include CO2, CH4, H2, and NH3, for gas uptakes as low as 0.04 mmol or 1.8 mg of CO2. We estimate that this method allows for the screening of at least 30-96 sorbents (in triplicate) or 90-264 sorbents (singles) per day, representing at least a 90-3000 times reduction in the time required for equivalent analysis.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article