Clinical Utility and Validation of the Acoustic Voice Quality and Acoustic Breathiness Indexes for Voice Disorder Assessment in English Speakers.
J Clin Med
; 12(24)2023 Dec 14.
Article
em En
| MEDLINE
| ID: mdl-38137748
ABSTRACT
BACKGROUND:
While several acoustic voice metrics are available for clinical voice assessment, there remains a significant need for reliable and ecologically valid tools. The Acoustic Voice Quality Index version 03.01 (AVQI-3) and Acoustic Breathiness Index (ABI) hold potential due to their comprehensive assessment approach, incorporating diverse voice aspects. However, these tools still need to be validated in English-speaking populations.METHODS:
This study assessed the discriminatory accuracy and validity of AVQI-3 and ABI in 197 participants, including 148 with voice disorders. Voice samples were collected, followed by AVQI-3 and ABI calculations. Additionally, auditory-perceptual assessments were conducted by a panel of speech-language pathologists.RESULTS:
AVQI-3 and ABI effectively identified disordered voice quality, evidenced by high accuracy (AUCs 0.84, 0.89), sensitivity, and specificity (thresholds AVQI-3 = 1.17, ABI = 2.35). Strong positive correlations were observed with subjective voice quality assessments (rs = 0.72, rs = 0.77, p < 0.001).CONCLUSIONS:
The study highlights AVQI-3 and ABI as promising instruments for clinically assessing voice disorders in U.S. English speakers, underscoring their utility in clinical practice and voice research.
Texto completo:
1
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article