Your browser doesn't support javascript.
loading
Single-Ion Counting with an Ultra-Thin-Membrane Silicon Carbide Sensor.
Sangregorio, Enrico; Calcagno, Lucia; Medina, Elisabetta; Crnjac, Andreo; Jaksic, Milko; Vignati, Anna; Romano, Francesco; Milluzzo, Giuliana; De Napoli, Marzio; Camarda, Massimo.
Afiliação
  • Sangregorio E; Department of Physics and Astronomy "Ettore Majorana", University of Catania (Italy), Via Santa Sofia 64, 95123 Catania, Italy.
  • Calcagno L; STLab srl, Via Anapo 53, 95126 Catania, Italy.
  • Medina E; Department of Physics and Astronomy "Ettore Majorana", University of Catania (Italy), Via Santa Sofia 64, 95123 Catania, Italy.
  • Crnjac A; STLab srl, Via Anapo 53, 95126 Catania, Italy.
  • Jaksic M; Physics Department, Università degli Studi di Torino, Via Pietro Giuria 1, 10125 Turin, Italy.
  • Vignati A; INFN-National Institute for Nuclear Physics, Turin Division, Via Pietro Giuria 1, 10125 Turin, Italy.
  • Romano F; Division of Experimental Physics, Ruder Boskovic Institute, 10000 Zagreb, Croatia.
  • Milluzzo G; Division of Experimental Physics, Ruder Boskovic Institute, 10000 Zagreb, Croatia.
  • De Napoli M; Physics Department, Università degli Studi di Torino, Via Pietro Giuria 1, 10125 Turin, Italy.
  • Camarda M; INFN-National Institute for Nuclear Physics, Turin Division, Via Pietro Giuria 1, 10125 Turin, Italy.
Materials (Basel) ; 16(24)2023 Dec 18.
Article em En | MEDLINE | ID: mdl-38138833
ABSTRACT
In recent times, ion implantation has received increasing interest for novel applications related to deterministic material doping on the nanoscale, primarily for the fabrication of solid-state quantum devices. For such applications, precise information concerning the number of implanted ions and their final position within the implanted sample is crucial. In this work, we present an innovative method for the detection of single ions of MeV energy by using a sub-micrometer ultra-thin silicon carbide sensor operated as an in-beam counter of transmitted ions. The SiC sensor signals, when compared to a Passivated Implanted Planar Silicon detector signal, exhibited a 96.5% ion-detection confidence, demonstrating that the membrane sensors can be utilized for high-fidelity ion counting. Furthermore, we assessed the angular straggling of transmitted ions due to the interaction with the SiC sensor, employing the scanning knife-edge method of a focused ion microbeam. The lateral dimension of the ion beam with and without the membrane sensor was compared to the SRIM calculations. The results were used to discuss the potential of such experimental geometry in deterministic ion-implantation schemes as well as other applications.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article