Your browser doesn't support javascript.
loading
Assessment of Muscle Coordination Changes Caused by the Use of an Occupational Passive Lumbar Exoskeleton in Laboratory Conditions.
Iranzo, Sofía; Belda-Lois, Juan-Manuel; Martinez-de-Juan, Jose Luis; Prats-Boluda, Gema.
Afiliação
  • Iranzo S; Instituto de Biomecánica de Valencia, Universitat Politècnica de València, 46022 Valencia, Spain.
  • Belda-Lois JM; Instituto de Biomecánica de Valencia, Universitat Politècnica de València, 46022 Valencia, Spain.
  • Martinez-de-Juan JL; Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, 46022 Valencia, Spain.
  • Prats-Boluda G; Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, 46022 Valencia, Spain.
Sensors (Basel) ; 23(24)2023 Dec 05.
Article em En | MEDLINE | ID: mdl-38139478
ABSTRACT
The introduction of exoskeletons in industry has focused on improving worker safety. Exoskeletons have the objective of decreasing the risk of injury or fatigue when performing physically demanding tasks. Exoskeletons' effect on the muscles is one of the most common focuses of their assessment. The present study aimed to analyze the muscle interactions generated during load-handling tasks in laboratory conditions with and without a passive lumbar exoskeleton. The electromyographic data of the muscles involved in the task were recorded from twelve participants performing load-handling tasks. The correlation coefficient, coherence coefficient, mutual information, and multivariate sample entropy were calculated to determine if there were significant differences in muscle interactions between the two test conditions. The results showed that muscle coordination was affected by the use of the exoskeleton. In some cases, the exoskeleton prevented changes in muscle coordination throughout the execution of the task, suggesting a more stable strategy. Additionally, according to the directed Granger causality, a trend of increasing bottom-up activation was found throughout the task when the participant was not using the exoskeleton. Among the different variables analyzed for coordination, the most sensitive to changes was the multivariate sample entropy.