Your browser doesn't support javascript.
loading
Microfluidic bead-based biosensor: Ultrasensitive ctDNA detection based on duplex-functional split-DNAzyme and dendritic enzyme-free signal amplification.
Fu, Xin; Yang, Mei; Zhang, He; Wang, Qing; Fu, Yu; Liu, Qiong.
Afiliação
  • Fu X; Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China.
  • Yang M; Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China.
  • Zhang H; Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China. Electronic address: mzhang_he@126.com.
  • Wang Q; Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China.
  • Fu Y; Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China.
  • Liu Q; Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China.
Anal Biochem ; 687: 115457, 2024 04.
Article em En | MEDLINE | ID: mdl-38184137
ABSTRACT
Circulating tumor DNA (ctDNA) is a crucial cancer biomarker for early or noninvasive monitoring, which is essential for developing ultrasensitive and selective assays in cancer diagnosis and treatment. Herein, a cascade signal amplification of duplex-functional split-DNAzyme and dendritic probes was proposed for ultrasensitive and specific detection of nasopharyngeal carcinoma-associated Epstein-Barr virus (EBV) DNA on microfluidic microbead array chips. With the assistance of Pb2+, the duplex-functional split-DNAzyme recognizes EBV DNA and then rapidly cleaves the substrate strand. Subsequently, the released target could be recycled, and its exposed capture probe, triggered the dendritic enzyme-free signal amplification. As the enhanced mass transfer capability, target recycling, and dendritic DNA structure signal amplification inherent to microfluidic bead arrays were integrated, it achieved an excellent detection limit of 0.36 fM and a wide linear range of 1 fM∼103 fM. Further, it was applied to content detect simulated samples of EBV DNA, recovery ranged from 97.2 % to 108.1 %, and relative standard deviation (RSD) from 3.3 % to 5.9 %, exhibiting satisfactory recovery results. The developed microfluidic biosensor was a high-sensitivity and anti-interference system for ctDNA analysis, with minimal reagent volumes (microlitres) required. Thus, it is a promising platform for ctDNA at the lowest level at their earliest incidence.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Infecções por Vírus Epstein-Barr / DNA Catalítico Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Infecções por Vírus Epstein-Barr / DNA Catalítico Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article