Your browser doesn't support javascript.
loading
Wearable Microneedle Patch for Transdermal Electrochemical Monitoring of Urea in Interstitial Fluid.
Dervisevic, Muamer; Jara Fornerod, Maximiliano Jesus; Harberts, Jann; Zangabad, Parham Sahandi; Voelcker, Nicolas H.
Afiliação
  • Dervisevic M; Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.
  • Jara Fornerod MJ; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia.
  • Harberts J; Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.
  • Zangabad PS; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia.
  • Voelcker NH; Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.
ACS Sens ; 9(2): 932-941, 2024 02 23.
Article em En | MEDLINE | ID: mdl-38252743
ABSTRACT
Microneedle-based wearable electrochemical biosensors are the new frontier in personalized health monitoring and disease diagnostic devices that provide an alternative tool to traditional blood-based invasive techniques. Advancements in micro- and nanofabrication technologies enabled the fabrication of microneedles using different biomaterials and morphological features with the aim of overcoming existing challenges and enhancing sensing performance. In this work, we report a microneedle array featuring conductive recessed microcavities for monitoring urea levels in the interstitial fluid of the skin. Microcavities are small pockets on the tip of each microneedle that can accommodate the sensing layer, provide protection from delamination during skin insertion or removal, and position the sensing layer in a deep layer of the skin to reach the interstitial fluid. The wearable urea patch has shown to be highly sensitive and selective in monitoring urea, with a sensitivity of 2.5 mV mM-1 and a linear range of 3 to 18 mM making it suitable for monitoring urea levels in healthy individuals and patients. Our ex vivo experiments have shown that recessed microcavities can protect the sensing layer from delamination during skin insertion and monitor changing urea levels in interstitial fluid. This biocompatible platform provides alternative solutions to the critical issue of maintaining the performance of the biosensor upon skin insertion and holds great potential for advancing transdermal sensor technology.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Líquido Extracelular / Dispositivos Eletrônicos Vestíveis Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Líquido Extracelular / Dispositivos Eletrônicos Vestíveis Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article