Your browser doesn't support javascript.
loading
The Precision, Inter-Rater Reliability, and Accuracy of a Handheld Scanner Equipped with a Light Detection and Ranging Sensor in Measuring Parts of the Body-A Preliminary Validation Study.
Callegari, Enrica; Agnolucci, Jacopo; Angiola, Francesco; Fais, Paolo; Giorgetti, Arianna; Giraudo, Chiara; Viel, Guido; Cecchetto, Giovanni.
Afiliação
  • Callegari E; Unit of Legal Medicine and Toxicology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Falloppio 50, 35100 Padova, Italy.
  • Agnolucci J; Unit of Legal Medicine and Toxicology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Falloppio 50, 35100 Padova, Italy.
  • Angiola F; Unit of Legal Medicine and Toxicology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Falloppio 50, 35100 Padova, Italy.
  • Fais P; Unit of Legal Medicine, Department of Medical and Surgical Sciences, University of Bologna, Via Zamboni 33, 40126 Bologna, Italy.
  • Giorgetti A; Unit of Legal Medicine, Department of Medical and Surgical Sciences, University of Bologna, Via Zamboni 33, 40126 Bologna, Italy.
  • Giraudo C; Unit of Radiology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35100 Padova, Italy.
  • Viel G; Unit of Legal Medicine and Toxicology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Falloppio 50, 35100 Padova, Italy.
  • Cecchetto G; Unit of Legal Medicine and Toxicology, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Falloppio 50, 35100 Padova, Italy.
Sensors (Basel) ; 24(2)2024 Jan 13.
Article em En | MEDLINE | ID: mdl-38257593
ABSTRACT

BACKGROUND:

Anthropometric measurements play a crucial role in medico-legal practices. Actually, several scanning technologies are employed in post-mortem investigations for forensic anthropological measurements. This study aims to evaluate the precision, inter-rater reliability, and accuracy of a handheld scanner in measuring various body parts.

METHODS:

Three independent raters measured seven longitudinal distances using an iPad Pro equipped with a LiDAR sensor and specific software. These measurements were statistically compared to manual measurements conducted by an operator using a laser level and a meterstick (considered the gold standard).

RESULTS:

The Friedman test revealed minimal intra-rater variability in digital measurements. Inter-rater variability analysis yielded an ICC = 1, signifying high agreement among the three independent raters. Additionally, the accuracy of digital measurements displayed errors below 1.5%.

CONCLUSIONS:

Preliminary findings demonstrate that the pairing of LiDAR technology with the Polycam app (ver. 3.2.11) and subsequent digital measurements with the MeshLab software (ver. 2022.02) exhibits high precision, inter-rater agreement, and accuracy. Handheld scanners show potential in forensic anthropology due to their simplicity, affordability, and portability. However, further validation studies under real-world conditions are essential to establish the reliability and effectiveness of handheld scanners in medico-legal settings.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pesquisadores / Antropologia Forense Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pesquisadores / Antropologia Forense Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article