Your browser doesn't support javascript.
loading
Tear Samples for Protein Extraction: Comparative Analysis of Schirmer's Test Strip and Microcapillary Tube Methods.
Tham, May Ling; Mahmud, Aidalina; Abdullah, Maha; Md Saleh, Rafidah; Mohammad Razali, Amirah; Cheah, Yoke Kqueen; Mohd Taib, Niazlin; Ho, Kok Lian; Mahmud, Mazaya; Mohd Isa, Muhammad.
Afiliação
  • Tham ML; Department of Ophthalmology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Mahmud A; Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Abdullah M; Department of Pathology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Md Saleh R; Department of Ophthalmology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Mohammad Razali A; Department of Ophthalmology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Cheah YK; Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Mohd Taib N; Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Ho KL; Department of Pathology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Mahmud M; Department of Ophthalmology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
  • Mohd Isa M; Department of Ophthalmology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, MYS.
Cureus ; 15(12): e50972, 2023 Dec.
Article em En | MEDLINE | ID: mdl-38259376
ABSTRACT

INTRODUCTION:

Tear sampling is an attractive option for collecting biological samples in ophthalmology clinics, as it offers a non-invasive alternative to other invasive techniques. However, there are many tear sampling methods still in consideration. This study explores the suitability of Schirmer's test strip and microcapillary tube as reliable and satisfactory methods for tear sampling.

METHODS:

Tear samples were collected from eight healthy volunteers using the standard Schirmer's test strip method with or without anesthesia and microcapillary tubes. The total tear protein concentrations were analyzed via spectrophotometry and bicinchoninic acid (BCA) protein assay. The protein profile was determined by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE). The optimal wetting length of Schirmer's strip and suitable buffer solutions were compared. Discomfort levels reported by participants and the ease of execution for ophthalmologists were also evaluated.

RESULTS:

Tear samples exhibited typical protein profiles as shown by SDS-PAGE. The mean total protein obtained from an optimum wetting length of 20 mm using Schirmer's strip without anesthesia in phosphate-buffered saline (PBS) yielded substantial quantities of protein as measured by nanophotometer (220.20 ± 67.43 µg) and the BCA protein assay (210.34 ± 59.46 µg). This method collected a significantly higher quantity of protein compared to the microcapillary tube method (p=0.004) which was much more difficult to standardize. The clinician found it harder to utilize microcapillary tubes, while participants experienced higher insecurity and less discomfort with the microcapillary tube method. PBS used during the tear protein extraction process eluted higher tear protein concentration than ammonium bicarbonate, although the difference was not statistically significant. Using anaesthesia did not ease the sampling procedure substantially and protein quantity was maintained.

CONCLUSION:

Good quality and quantity of protein from tear samples were extracted with the optimized procedure. Schirmer's strip test in the absence of local anesthesia provided a standard, convenient, and non-invasive method for tear collection.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article