Your browser doesn't support javascript.
loading
Clinical value of 18F-PSMA-1007 PET/MRI in primary staging of patients with intermediate- to high-risk prostate cancer.
Ali, Ismail; Rezk, Mahmoud; Hamouda, Dalia; Talaat, Omnia; Omar, Yehia; Abdel Tawab, Mohamed; Nasr, Ibrahim.
Afiliação
  • Ali I; Radiology Department, Faculty of Human Medicine, Zagazig University, Zagazig, Faculty of medicine street, Zagazig, Sharkia, 44519, Egypt.
  • Rezk M; Radiology Department, National cancer Institute, Cairo University, Cairo, 11796, Egypt.
  • Hamouda D; Medical Oncology Department, Faculty of Human Medicine, Zagazig University, Zagazig, 44519, Egypt.
  • Talaat O; Radiation Oncology Department, National Cancer Institute, Cairo University, Cairo, 11796, Egypt.
  • Omar Y; Director of PET/MRI unit, Misr Radiology Cente, Cairo, 11766, Egypt.
  • Abdel Tawab M; Radiology Department, Faculty of Human Medicine, Alazhar University, Cairo, 11651, Egypt.
  • Nasr I; Clinical Oncology and Nuclear Medicine Department, Faculty of Human Medicine, Zagazig University, Zagazig, 44519, Egypt.
Br J Radiol ; 97(1155): 622-631, 2024 Feb 28.
Article em En | MEDLINE | ID: mdl-38265254
ABSTRACT

OBJECTIVE:

To assess the utility of 18F-PSMA-1007 PET/MRI in initial staging of intermediate- to high-risk prostate cancer (HRPCa).

METHODS:

A total of 46 patients with pathologically verified intermediate and/or HRPCa who underwent 18F-PSMA-1007 PET/MRI with dedicated pelvic high-resolution multiparametric MRI (mpMRI) were included.

RESULTS:

PET/MRI showed 100% sensitivity (SN), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and accuracy in detecting seminal vesicle (SV) and rectal invasion, versus 87.5%, 100%, 100% 93.8%, 95.7% and 50%, 100%,100%, 95.5%, and 95.7% for mpMRI respectively. However, PET/MRI had poor SN (40% and 0%) but high SP (94.4% and 100%) in detection of UB and neurovascular bundle (NV) invasion compared to 100% SN and SP for mpMRI. PET/MRI demonstrated stronger TNM staging agreement with the gold standard than mpMRI-WBMRI. It demonstrated concordance with T, N, and M stages in 40, 41, and 36 patients (k 0.84, 0.60, and 0.68, respectively) versus 29, 33, and 31 patients (k 0.54, 0.22, and 0.50) with accurate over all staging of 38/46 patients versus 30/46 patients (K 0.52 versus 0.22).

CONCLUSION:

18F-PSMA-1007 PET/MRI is a promising imaging modality with high diagnostic accuracy in staging intermediate- and HRPCa; it improves local tumour evaluation and provides precise TNM staging. ADVANCES IN KNOWLEDGE 18F-PSMA-1007 PET/MRI could have high diagnostic accuracy as shown in the current study for staging HRPCa patients that is crucial for treatment selection. We think that our study will contribute to the body of knowledge and improve the literature surrounding the clinical uses of integrated 18F-PSMA-1007 PET/MRI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oligopeptídeos / Neoplasias da Próstata / Niacinamida / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oligopeptídeos / Neoplasias da Próstata / Niacinamida / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article