Your browser doesn't support javascript.
loading
Preliminary study on the computer-based optokinetic nystagmus analyzer to detect the visual acuity of preschool children.
Min, Xia; Rehman, Faisal Ul; Jing, Wang; Nan, Chen; Cheng, Che; Yu, Song.
Afiliação
  • Min X; Department of Ophthalmology, Weihai Central Hospital, Weihai, Shandong, China.
  • Rehman FU; Precision Medicine Center of Oncology, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, Shangdong, China.
  • Jing W; Department of Research and Development, Pengfengcheng Medical Technology, Qingdao, Shangdong, China.
  • Nan C; Department of Ophthalmology, Weihai Central Hospital, Weihai, Shandong, China.
  • Cheng C; Department of Ophthalmology, Weihai Central Hospital, Weihai, Shandong, China.
  • Yu S; Department of Management and Marketing, University of Petroleum Huadong, Qingdao, Shangdong, China.
Indian J Ophthalmol ; 72(Suppl 2): S162-S166, 2024 Feb 01.
Article em En | MEDLINE | ID: mdl-38271412
ABSTRACT
The purpose of this study is to examine the viability, precision, and consistency of a computer-based optokinetic nystagmus analyzer (nystagmus meter) for diagnosing eyesight in preschoolers. A total of 59 subjects who could pass the log of minimum angle of resolution (LogMAR) visual acuity chart were divided into three groups by age, 4-, 5-, and 6-year-old groups, and their visual acuity was tested with nystagmus meter. The percentage of children in each age group that could be detected by nystagmus was recorded along with the differences between these groups. The correlation between the test results from the two methods was found for each age group using the correlation coefficient method. Repeated measurements were used to assess the two visual acuity values of the measured nystagmus, and the repeatability of the two measurement techniques for different age groups was compared. The overall measurability of the visual acuity detected by nystagmus was 93.22%, and the measurability of the 4-, 5-, and 6-year-old groups was 90%, 95%, and 94.74%, respectively. There was no statistically significant difference in the measurability of subjects among all age groups (P = 1.0). The outcomes of the LogMAR visual acuity chart had a negative correlation with the visual acuity measured by the nystagmus meter. The overall correlation coefficient R value was -0.80, and the correlation coefficient R value of the 4-, 5-, and 6-year-old groups was -0.79, -0.76, and -0.87, respectively. The nystagmus meter has good feasibility, accuracy, and stability in visual acuity testing and can be used for visual acuity testing in children.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nistagmo Patológico / Nistagmo Optocinético Tipo de estudo: Diagnostic_studies Limite: Child, preschool / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nistagmo Patológico / Nistagmo Optocinético Tipo de estudo: Diagnostic_studies Limite: Child, preschool / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article