Your browser doesn't support javascript.
loading
Increased Pulmonary-Aortic Interspace in Fetal Right Aortic Arch: A Matched Case-Control Study.
Bet, Bo B; van Steijn, Agnes E; Linskens, Ingeborg H; Knobbe, Ingmar; van Leeuwen, Elisabeth; Pajkrt, Eva; Clur, Sally-Ann.
Afiliação
  • Bet BB; Department of Obstetrics and Gynecology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands.
  • van Steijn AE; Amsterdam Reproduction and Development, Amsterdam, The Netherlands.
  • Linskens IH; Department of Obstetrics and Gynecology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands.
  • Knobbe I; Amsterdam Reproduction and Development, Amsterdam, The Netherlands.
  • van Leeuwen E; Department of Obstetrics and Gynecology, Amsterdam UMC Location Vrije Universiteit, Amsterdam, The Netherlands.
  • Pajkrt E; Amsterdam Reproduction and Development, Amsterdam, The Netherlands.
  • Clur SA; Department of Pediatric Cardiology, Amsterdam UMC Location Vrije Universiteit, Amsterdam, The Netherlands.
Fetal Diagn Ther ; 51(3): 225-234, 2024.
Article em En | MEDLINE | ID: mdl-38272013
ABSTRACT

INTRODUCTION:

The prenatal detection rate of a right aortic arch (RAA) has increased with the implementation of the three-vessel view (3VV) to the second-trimester anomaly scan formed by the pulmonary artery (PA), aorta (Ao), and superior vena cava (SVC). We examined the value of measuring the distance between PA and Ao in the 3VV in cases with an RAA.

METHODS:

We conducted a case-control study in which fetuses with an isolated RAA were matched to 3 healthy controls. Using 3VV images, the distances between PA, Ao, and SVC were measured and the ratio between PA to Ao (PAAo) distance and Ao to SVC (AoSVC) distance was calculated.

RESULTS:

Fifty-four RAA cases and 162 matched controls were included. The mean absolute distance PAAo was 3.1 mm in cases and 1.8 mm in controls (p < 0.001), and the mean PAAo/AoSVC ratio was 2.9 and 1.4, respectively (p < 0.001). The ROC curve of PAAo/AoSVC ratio showed a cut-off point of 1.9 with sensitivity and specificity over 87% for the diagnosis of RAA.

CONCLUSIONS:

The pulmonary-aortic interspace and the PAAo/AoSVC ratio were significantly larger for RAA cases as compared to controls. If an increased pulmonary-aortic interspace is observed, a PAAo/AoSVC of ≥1.9 can be helpful in the diagnosis of an RAA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Torácica / Artéria Pulmonar / Ultrassonografia Pré-Natal Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Torácica / Artéria Pulmonar / Ultrassonografia Pré-Natal Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2024 Tipo de documento: Article