Your browser doesn't support javascript.
loading
Accuracy comparison of scan segmental sequential ranges with two intraoral scanners for maxilla and mandible.
Liu, Chih-Te; Chen, Jen-Hao; Du, Je-Kang; Hung, Chun-Cheng; Lan, Ting-Hsun.
Afiliação
  • Liu CT; Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.
  • Chen JH; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Du JK; Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.
  • Hung CC; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Lan TH; Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.
J Dent Sci ; 19(1): 466-472, 2024 Jan.
Article em En | MEDLINE | ID: mdl-38303839
ABSTRACT
Background/

purpose:

The accuracy of a full-arch scan by using an intraoral scanner should be validated under clinical conditions. This study aimed to compare the accuracy of full-arch digital impressions in the maxilla and mandible using two intra oral scanners with three different scan segmental sequential ranges. Materials and

methods:

A dental model with 28 teeth in their normal positions served as the reference. Sixty full-arch scans were performed using Trios 3 and Trios 4, employing scanning strategy O (manufacturer's original method), OH (segmental sequential ranges one half), and TQ (segmental sequential ranges third quarter). Trueness was evaluated by comparing digital impressions with a reference dataset using specialized software. One-way ANOVA and Tukey tests assessed differences between the groups.

Results:

For Trios 3 on the maxilla, no significant difference was found among the groups of trueness; in the mandible, strategy O exhibited a significant difference (P = 0.008) with the highest deviation. For Trios 4 on the maxilla, strategy TQ demonstrated the lowest deviation with a significant difference (P = 0.006); in the mandible, no significant difference was found among the groups of trueness.

Conclusion:

Strategy TQ exhibited the best trueness for Trios 3 and Trios 4, suggesting it may be preferred for higher accuracy. Clinicians should consider these findings when selecting scanning strategies and intraoral scanners for specific cases.