Your browser doesn't support javascript.
loading
Late acquired coronary aneurysm and restenosis after bioresorbable vascular scaffold implantation: a case report.
Micari, Antonino; Dimartino, Angelo; Donato, Rocco; Vizzari, Giampiero; Andò, Giuseppe.
Afiliação
  • Micari A; Department of Clinical and Experimental Medicine, University of Messina and AOU Policlinico 'Gaetano Martino', Via Consolare Valeria, 98122 Messina, Italy.
  • Dimartino A; Department of Clinical and Experimental Medicine, University of Messina and AOU Policlinico 'Gaetano Martino', Via Consolare Valeria, 98122 Messina, Italy.
  • Donato R; Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, University of Messina and AOU Policlinico 'Gaetano Martino', Via Consolare Valeria, 98122 Messina, Italy.
  • Vizzari G; Department of Clinical and Experimental Medicine, University of Messina and AOU Policlinico 'Gaetano Martino', Via Consolare Valeria, 98122 Messina, Italy.
  • Andò G; Department of Clinical and Experimental Medicine, University of Messina and AOU Policlinico 'Gaetano Martino', Via Consolare Valeria, 98122 Messina, Italy.
Eur Heart J Case Rep ; 8(2): ytae065, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38332923
ABSTRACT

Background:

Although the technology of bioresorbable vascular scaffold (BVS) aroused the peak of interest a few years ago and currently remains available only as part of experimental research, patients who have had BVS implanted should be still carefully monitored to detect possible long-term complications. Case

summary:

We present the case of a 47-year-old man who had received BVS implantation for ST-segment elevation myocardial infarction. Six years later, computed tomography coronary angiography (CTCA) demonstrated in-segment restenosis in between two newly formed coronary aneurysms at the site of the implanted BVS. The patient received successful optical coherence tomography-guided percutaneous intervention with a new metallic drug-eluting stent implantation.

Discussion:

Our case demonstrates that coronary aneurysms can be well characterized with CTCA and are often incidentally discovered as they cause no symptoms. The incidence of coronary aneurysm at the site of a previously implanted BVS is not defined, and little is known about the pathophysiology and evolution of these lesions. Therefore, the decision to proceed with conservative management or intervention must be tailored to the clinical conditions of the patient, the anatomy, the rapidity of growth, and the possible thrombotic burden.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Qualitative_research Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Qualitative_research Idioma: En Ano de publicação: 2024 Tipo de documento: Article