Experimental study of the bond behavior of 400MPa grade hot-rolled ribbed steel bars in steel fibre reinforced concrete.
Zhao, Minglei; Li, Jie; Xie, Yi Min; Shen, Jianhu; Li, Changyong.
Afiliação
  • Zhao M; School of Engineering, RMIT University, Melbourne, 3001, Australia.
  • Li J; International Joint Research Lab for Eco-Building Materials and Engineering of Henan, North China University of Water Resources and Electric Power, Zhengzhou, 450045, China.
  • Xie YM; School of Engineering, RMIT University, Melbourne, 3001, Australia. Jie.li@rmit.edu.au.
  • Shen J; School of Engineering, RMIT University, Melbourne, 3001, Australia.
  • Li C; School of Engineering, RMIT University, Melbourne, 3001, Australia.
Sci Rep ; 14(1): 4066, 2024 Feb 19.
Article em En | MEDLINE | ID: mdl-38374193
ABSTRACT
Present studies show that steel fibres can improve the bond of steel bar in steel fibre reinforced concrete (SFRC) with a correlation to the fibre factor and the fibre distribution uniformity. As a foundation of high-flowability SFRC working together with 400 MPa grade hot-rolled ribbed (HRB400) steel bar in reinforced structures, the bond between them was evaluated through a series of pull-out testing on 48 specimens with a central arranged steel bar. The bond behaviours of steel bar were estimated with a constant bond length of 5d (d is the diameter of steel bar) embedded in high-flowability SFRC, the main research parameters included the ingot mill steel fibres with a fibre volume fraction varied from 0.8 to 2.0%, the strength grade C40 and C50 of SFRC or referenced conventional concrete, and the diameter of steel bars varied from 14 to 20 mm. Results showed that the high-flowability SFRC compacted with a slight vibration is beneficial to improve the bond failure pattern since steel fibres effectively eliminate the crack appeared on the SFRC blocks during the pulling out of steel bar, leading to all specimens failed with the steel bar pull out of SFRC blocks. The bond strength was dominant by the SFRC strength, and obviously strengthened with the increase of fibre volume fraction, while the peak-slip was slightly influenced by the diameter of steel bar. By conducting analyses of test data, equations for calculating the bond strength and the peak-slip are proposed accounting for the effect of steel fibres. Then the predicting method for the anchorage length is suggested linking with different design codes for concrete structures. Compared with test results of this study, a little shorter anchorage length of steel bar in SFRC is obtained from the specification of Chinese code JGJ/T46, which should be noticed to ensure a rational anchorage of ribbed steel bar in SFRC with ingot mill steel fibres.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article