Chiral separation of propranolol by electrokinetic chromatography using nanodiamonds and human serum albumin as a pseudo-stationary phase in river water.
Lanaro, Verónica M; Sombra, Lorena L; Altamirano, Jorgelina C; Almeida, César A; Stege, Patricia W.
Afiliação
  • Lanaro VM; Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, San Luis, Argentina.
  • Sombra LL; Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, San Luis, Argentina.
  • Altamirano JC; IANIGLA, Laboratorio de Química Ambiental, Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales, Mendoza, Argentina.
  • Almeida CA; CONICET (Consejo Nacional de Investigaciones Científicas y Tecnológicas), San Luis, Argentina.
  • Stege PW; Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, San Luis, Argentina.
Chirality ; 36(2): e23640, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38384157
ABSTRACT
Propranolol is currently considered as an emerging contaminant in water bodies. In this study, R- and S-propranolol were determined in river samples by electrokinetic chromatography (EKC) using nanodiamonds (NDs) and human serum albumin (HSA) as a pseudo-stationary phase in order to achieve enantioseparation. Previously, river samples were preconcentrated using a column filled with Amberlite® IR-120 and Dowex® 50WX8 resins. The setting up of influential factors such as temperature, voltage, pH, and HSA and NDs concentration is accurately described along this manuscript. A multivariate study and optimization was carried out to obtain the enantioseparation of propranolol (Rs = 2.91), which was reached under the following experimental conditions voltage of 16 kV, temperature of 16°C, phosphate buffer pH 9.5, NDs of 0.20%, and HSA of 15 µmol l-1 . The recoveries of analytes under optimal conditions were higher than 98%. The limits of detection were 0.85 µg l-1 for R- and S-propranolol. The method was applied to real samples, and the obtained results in three different water sources studied were 1.02, 0.59, and 0.30 µg l-1 for the R-enantiomer and 0.99, 0.54, and 0.28 µg l-1 for the S-enantiomer. The accuracy of the proposed methodology (including bias and precision) has allowed us to propose it as a successful tool for the control of water quality.