Your browser doesn't support javascript.
loading
Cerebrovascular Responses in a Patient with Lundberg B Waves Following Subarachnoid Haemorrhage Assessed with a Novel Non-Invasive Brain Pulse Monitor: A Case Report.
Teo, Elliot John; Petautschnig, Sigrid; Hellerstedt, Jack; Grace, Sally A; Savage, Jacqui S; Fafiani, Brendan; Smith, Paul Daniel; Jhamb, Ashu; Haydon, Timothy; Dixon, Barry.
Afiliação
  • Teo EJ; Cyban Pty Ltd, Melbourne, Victoria, Australia.
  • Petautschnig S; Department of Critical Care Medicine, St Vincent's Hospital, Melbourne, Victoria, Australia.
  • Hellerstedt J; Cyban Pty Ltd, Melbourne, Victoria, Australia.
  • Grace SA; Department of Critical Care Medicine, St Vincent's Hospital, Melbourne, Victoria, Australia.
  • Savage JS; Cyban Pty Ltd, Melbourne, Victoria, Australia.
  • Fafiani B; Cyban Pty Ltd, Melbourne, Victoria, Australia.
  • Smith PD; Cyban Pty Ltd, Melbourne, Victoria, Australia.
  • Jhamb A; Cyban Pty Ltd, Melbourne, Victoria, Australia.
  • Haydon T; Department of Neurosurgery, St Vincent's Hospital, Melbourne, Victoria, Australia.
  • Dixon B; University of Melbourne Medical School, Melbourne, VIC, Australia.
Med Devices (Auckl) ; 17: 73-87, 2024.
Article em En | MEDLINE | ID: mdl-38404631
ABSTRACT
Subarachnoid haemorrhage (SAH) can trigger a range of poorly understood cerebrovascular responses that may play a role in delayed cerebral ischemia. The brain pulse monitor is a novel non-invasive device that detects a brain photoplethysmography signal that provides information on intracranial pressure (ICP), compliance, blood flow and tissue oxygen saturation. We monitored the cerebrovascular responses in a patient with Lundberg B waves following a SAH. The patient presented with a Fischer grade 4 SAH that required urgent left posterior communicating artery aneurysm coiling and ventricular drain insertion. On hospital day 4 oscillations or spikes on the invasive ICP were noted, consistent with Lundberg B waves. Brain pulse monitoring demonstrated concurrent pulse waveform features consistent with reduced brain compliance and raised ICP over both brain hemispheres. Oxygen levels also demonstrated slow oscillations correlated with the ICP spikes. Brief infrequent episodes of reduced and absent brain pulses were also noted over the right hemisphere. Our findings suggest that the brain pulse monitor holds promise for early detection of delayed cerebral ischemia and could offer insights into the vascular mechanisms at play.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article