Your browser doesn't support javascript.
loading
A simple and reliable interenzyme distance regulation strategy based on a DNA quadrangular prism scaffold for ultrasensitive ochratoxin A detection.
Wang, Rong; Kong, Lingqi; Liu, Ying; Chai, Yaqin; Yuan, Ruo.
Afiliação
  • Wang R; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
  • Kong L; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
  • Liu Y; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
  • Chai Y; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China. Electronic address: yqchai@swu.edu.cn.
  • Yuan R; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China. Electronic address: yuanruo@swu.edu.cn.
Food Chem ; 446: 138872, 2024 Jul 15.
Article em En | MEDLINE | ID: mdl-38442680
ABSTRACT
Developing sensitive and accurate Ochratoxin A (OTA) detection methods is essential for food safety. Herein, a simple and reliable strategy for regulating interenzyme distance based on a rigid DNA quadrangular prism as a scaffold was proposed to establish a new electrochemical biosensor for ultrasensitive detection of OTA. The interenzyme distances were precisely adjusted by changing the sequences of the hybridized portions of hairpins SH1 and SH2 to the DNA quadrangular prism, avoiding the complexity and instability of the previous DNA scaffold-based enzyme spacing adjustment strategies. The electrochemical biosensor constructed at the optimal interenzyme distance (10.4 nm) achieved sensitive detection of OTA in a dynamic concentration range from 10 fg/mL to 250 ng/mL with a detection limit of 3.1 fg/mL. In addition, the biosensor was applied to quantify OTA in real samples, exhibiting great application potential in food safety.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Ocratoxinas Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Ocratoxinas Idioma: En Ano de publicação: 2024 Tipo de documento: Article