New Methodology to Evaluate and Optimize Indoor Ventilation Based on Rapid Response Sensors.
Durán Del Amor, María Del Mar; Baeza Caracena, Antonia; Esquembre, Francisco; Llorens Pascual Del Riquelme, Mercedes.
Afiliação
  • Durán Del Amor MDM; Department of Chemical Engineering, Faculty of Chemistry, Campus de Espinardo, University of Murcia, 30100 Murcia, Spain.
  • Baeza Caracena A; Department of Chemical Engineering, Faculty of Chemistry, Campus de Espinardo, University of Murcia, 30100 Murcia, Spain.
  • Esquembre F; Department of Mathematics, Faculty of Mathematics, Campus de Espinardo, University of Murcia, 30100 Murcia, Spain.
  • Llorens Pascual Del Riquelme M; Department of Chemical Engineering, Faculty of Chemistry, Campus de Espinardo, University of Murcia, 30100 Murcia, Spain.
Sensors (Basel) ; 24(5)2024 Mar 04.
Article em En | MEDLINE | ID: mdl-38475193
ABSTRACT
The recent pandemic increased attention to the need for appropriated ventilation and good air quality as efficient measures to achieve safe and healthy indoor air. This work provides a novel methodology for continuously evaluating ventilation in public areas using modern rapid response sensors (RRS). This methodology innovatively assesses the ventilation of a space by combining a quantitative estimation of the real air exchange in the space-obtained from CO2 experimental RRS measurements and the characteristics of and activity in the space-and indoor and outdoor RRS measurements of other pollutants, with healthy recommendations from different organisations. The methodology allows space managers to easily evaluate, in a continuous form, the appropriateness of their ventilation strategy, thanks to modern RRS measurements and direct calculations (implemented here in a web app), even in situations of full activity. The methodology improves on the existing standards, which imply the release of tracer gases and expert intervention, and could also be used to set a control system that measures continuously and adapts the ventilation to changes in indoor occupancy and activity, guaranteeing safe and healthy air in an energy-efficient way. Sample public concurrence spaces with different conditions are used to illustrate the methodology.