Your browser doesn't support javascript.
loading
Toward Translational Impact of Low-Glucose Strategies on Red Blood Cell Storage Optimization.
Soule, Logan D; Skrajewski-Schuler, Lauren; Branch, Stephen A; McMahon, Timothy J; Spence, Dana M.
Afiliação
  • Soule LD; Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan 48824, United States.
  • Skrajewski-Schuler L; Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, Michigan 48824, United States.
  • Branch SA; Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, Michigan 48824, United States.
  • McMahon TJ; Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, United States.
  • Spence DM; Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan 48824, United States.
ACS Pharmacol Transl Sci ; 7(3): 878-887, 2024 Mar 08.
Article em En | MEDLINE | ID: mdl-38481682
ABSTRACT
Transfusion of stored red blood cells (RBCs) to patients is a critical component of human healthcare. Following purification from whole blood, RBCs are stored in one of many media known as additive solutions for up to 42 days. However, during the storage period, the RBCs undergo adverse chemical and physical changes that are often collectively known as the RBC storage lesion. Storage of RBCs in additive solutions modified to contain physiological levels of glucose, as opposed to hyperglycemic levels currently used in most cases, reduces certain markers of the storage lesion, although intermittent doses of glucose are required to maintain normoglycemic conditions. Here, we describe an electrically actuated valving system to dispense small volumes of glucose into 100 mL PVC storage bags containing packed RBCs from human donors. The RBCs were stored in a conventional additive solution (AS-1) or a normoglycemic version of AS-1 (AS-1N) and common markers of stored RBC health were measured at multiple time points throughout storage. The automated feeding device delivered precise and predictable volumes of concentrated glucose to maintain physiological glucose levels for up to 37 days. Hemolysis, lactate accumulation, and pH values of RBCs stored in AS-1N were statistically equivalent to values measured in AS-1, while significant reductions in osmotic fragility and intracellular sorbitol levels were measured in AS-1N. The reduction of osmotic fragility and oxidative stress markers in a closed system may lead to improved transfusion outcomes for an important procedure affecting millions of people each year.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article