Your browser doesn't support javascript.
loading
Retinal complications post posterior chamber phakic intraocular lens implantation at a tertiary eye hospital in the Eastern Province of Saudi Arabia.
Aljindan, Mohanna; Albalawi, Nada; Alzaher, Fatimah; Hariri, Jumana; Bin Helayel, Halah; Alsubaie, Majed Fehaid; Khan, Omar; Aloqab, Aysha; Alarfaj, Ghufran; Sulaimani, Naif M.
Afiliação
  • Aljindan M; Ophthalmology Department, College of Medicine, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
  • Albalawi N; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
  • Alzaher F; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
  • Hariri J; Ophthalmology Department, King Salman Armed Forces Hospital, Tabuk, Saudi Arabia.
  • Bin Helayel H; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
  • Alsubaie MF; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
  • Khan O; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
  • Aloqab A; Anterior Segment Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia.
  • Alarfaj G; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
  • Sulaimani NM; Ophthalmology Department, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran, Saudi Arabia.
Int Ophthalmol ; 44(1): 141, 2024 Mar 16.
Article em En | MEDLINE | ID: mdl-38492122
ABSTRACT

PURPOSE:

Phakic intraocular lenses treat higher degrees of myopia not possible previously with conventional refractive surgery. The aim of this study is to report the incidence and risk factors of retinal complications after posterior chamber PIOL implantation and assess the differences in biometric parameters between patients who developed such complications versus those who did not.

METHODS:

This retrospective study recruited 514 patients who underwent ICL implantation to correct myopia at a tertiary eye hospital center in the Eastern province of Saudi Arabia. Follow up period was at least one year. Medical records of the patients were reviewed to obtain the required data. Associations between respondents' characteristics and retinal complications were evaluated using the Chi-squared test.

RESULTS:

The mean (SD) age was 27.7 (± 6.5) years ranging from 18 to 47. Laser treatment was performed in 14 cases (2.7%). Retinal complications occurred in six cases (1.2%). The risk of retinal complication was significantly higher among patients with high axial length (OR = 1.3, 95% CI 1.2, 1.4) and patients with high pre-spherical equivalent before ICL (OR = 1.09, 95% CI 1.03, 1.4).

CONCLUSION:

Patients with higher axial length and higher pre-spherical equivalent before ICL implantation are at high risk of retinal complications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lentes Intraoculares Fácicas / Miopia Limite: Adult / Humans País como assunto: Asia Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lentes Intraoculares Fácicas / Miopia Limite: Adult / Humans País como assunto: Asia Idioma: En Ano de publicação: 2024 Tipo de documento: Article