Your browser doesn't support javascript.
loading
Four-Color ImmunoSpot® Assays Requiring Only 1-3 mL of Blood Permit Precise Frequency Measurements of Antigen-Specific B Cells-Secreting Immunoglobulins of All Four Classes and Subclasses.
Yao, Lingling; Becza, Noémi; Maul-Pavicic, Andrea; Chepke, Jack; Kirchenbaum, Greg A; Lehmann, Paul V.
Afiliação
  • Yao L; Research & Development Department, Cellular Technology Limited, Shaker Heights, OH, USA.
  • Becza N; Research & Development Department, Cellular Technology Limited, Shaker Heights, OH, USA.
  • Maul-Pavicic A; Research & Development Department, Cellular Technology Limited, Shaker Heights, OH, USA.
  • Chepke J; Research & Development Department, Cellular Technology Limited, Shaker Heights, OH, USA.
  • Kirchenbaum GA; Research & Development Department, Cellular Technology Limited, Shaker Heights, OH, USA. greg.kirchenbaum@immunospot.com.
  • Lehmann PV; Research & Development Department, Cellular Technology Limited, Shaker Heights, OH, USA.
Methods Mol Biol ; 2768: 251-272, 2024.
Article em En | MEDLINE | ID: mdl-38502398
ABSTRACT
The B lymphocyte response can encompass four immunoglobulin (Ig) classes and four IgG subclasses, each contributing fundamentally different effector functions. Production of the appropriate Ig class/subclass is critical for both successful host defense and avoidance of immunopathology. The assessment of an antigen-specific B cell response, including its magnitude and Ig class/subclass composition, is most often confined to the antibodies present in serum and other biological fluids and neglects monitoring of the memorycell (Bmem) compartment capable of mounting a faster and more efficient antibody response following antigen reencounter. Here, we describe how the frequency and Ig class and IgG subclass use of an antigen-specific Bmem repertoire can be determined with relatively little labor and cost, requiring only 8 × 105 freshly isolated peripheral blood mononuclear cells (PBMC), or if additional cryopreservation and polyclonal stimulation is necessary, 3 × 106 PBMC per antigen. To experimentally validate such cell saving assays, we have documented that frequency measurements of antibody-secreting cells (ASC) yield results indistinguishable from those of enzymatic (ELISPOT) or fluorescent (FluoroSpot) versions of the ImmunoSpot® assay, including when the latter are detected in alternative fluorescent channels. Moreover, we have shown that frequency calculations that are based on linear regression analysis of serial PBMC dilutions using a single well per dilution step are as accurate as those performed using replicate wells. Collectively, our data highlight the capacity of multiplexed B cell FluoroSpot assays in conjunction with serial dilutions to significantly reduce the PBMC requirement for detailed assessment of antigen-specific B cells. The protocols presented here allow GLP-compliant high-throughput measurements which should help to introduce high-dimensional Bmem characterization into the standard immune monitoring repertoire.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Leucócitos Mononucleares / Linfócitos B Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Leucócitos Mononucleares / Linfócitos B Idioma: En Ano de publicação: 2024 Tipo de documento: Article