Your browser doesn't support javascript.
loading
Image-based dosimetry for [225Ac]Ac-PSMA-I&T therapy and the effect of daughter-specific pharmacokinetics.
Liubchenko, Grigory; Böning, Guido; Zacherl, Mathias; Rumiantcev, Mikhail; Unterrainer, Lena M; Gildehaus, Franz Josef; Brendel, Matthias; Resch, Sandra; Bartenstein, Peter; Ziegler, Sibylle I; Delker, Astrid.
Afiliação
  • Liubchenko G; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany. grigory.liubchenko@med.uni-muenchen.de.
  • Böning G; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
  • Zacherl M; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
  • Rumiantcev M; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
  • Unterrainer LM; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
  • Gildehaus FJ; Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, University of California Los Angeles, Los Angeles, CA, USA.
  • Brendel M; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
  • Resch S; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
  • Bartenstein P; SyNergy, University of Munich, Munich, Germany.
  • Ziegler SI; DZNE - German Center for Neurodegenerative Diseases, Munich, Germany.
  • Delker A; Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Marchioninstrasse 15, 81377, Munich, Germany.
Eur J Nucl Med Mol Imaging ; 51(8): 2504-2514, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38512484
ABSTRACT

PURPOSE:

Although 221Fr and 213Bi have sufficient gamma emission probabilities, quantitative SPECT after [225Ac]Ac-PSMA-I&T therapy remains challenging due to low therapeutic activities. Furthermore, 221Fr and 213Bi may underlie a different pharmacokinetics due to alpha recoil. We conducted a quantitative SPECT study and a urine analysis to investigate the pharmacokinetics of 221Fr and 213Bi and the impact on image-based lesion and kidney dosimetry.

METHODS:

Five patients (7.7 ± 0.2 MBq [225Ac]Ac-PSMA-I&T) underwent an abdominal SPECT/CT (1 h) at 24 and 48 h (Siemens Symbia T2, high-energy collimator, 440 keV/218 keV (width 20%), 78 keV (width 50%)). Quantitative SPECT was reconstructed using MAP-EM with attenuation and transmission-dependent scatter corrections and resolution modelling. Time-activity curves for kidneys (CT-based) and lesions (80% isocontour 24 h) were fitted mono-exponentially. Urine samples collected along with each SPECT/CT were measured in a gamma counter until secular equilibrium was reached.

RESULTS:

Mean kidney and lesion effective half-lives were as follows 213Bi, 27 ± 6/38 ± 10 h; 221Fr, 24 ± 6/38 ± 11 h; 78 keV, 23 ± 7/39 ± 13 h. The 213Bi-to-221Fr kidney SUV ratio increased by an average of 9% from 24 to 48 h. Urine analysis revealed an increasing 213Bi-to-225Ac ratio (24 h, 0.98 ± 0.15; 48 h, 1.08 ± 0.09). Mean kidney and lesion absorbed doses were 0.17 ± 0.06 and 0.36 ± 0.1 Sv RBE = 5 /MBq using 221Fr and 213Bi SPECT images, compared to 0.16 ± 0.05/0.18 ± 0.06 and 0.36 ± 0.1/0.38 ± 0.1 Sv RBE = 5 /MBq considering either the 221Fr or 213Bi SPECT.

CONCLUSION:

SPECT/CT imaging and urine analysis showed minor differences of up to 10% in the daughter-specific pharmacokinetics. These variances had a minimal impact on the lesion and kidney dosimetry which remained within 8%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article