Your browser doesn't support javascript.
loading
Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application.
Liu, Maozhu; Fan, Fei; Zhang, Jing; Fang, Shiyong; Bai, Yangjuan; Li, Yamei; Zou, Yuangao; An, Yunfei; Dai, Xinhua.
Afiliação
  • Liu M; Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Fan F; Department of Pharmacy, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Zhang J; West China School of Basic Medical Science & Forensic Medicine, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Fang S; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Bai Y; School of Forensic Medicine, Wannan Medical College, Wuhu, 241002, Anhui, China.
  • Li Y; Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Zou Y; Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • An Y; Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
  • Dai X; Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
Anal Bioanal Chem ; 416(12): 3073-3083, 2024 May.
Article em En | MEDLINE | ID: mdl-38514583
ABSTRACT
Diquat (DQ), paraquat (PQ), glufosinate (GLU), and glyphosate (GLYP) are commonly used herbicides that have been confirmed to be toxic to humans. Rapid and accurate measurements of these toxicants in clinical practice are beneficial for the correct diagnosis and timely treatment of herbicide-poisoned patients. The present study aimed to establish an efficient, convenient, and reliable method to achieve the simultaneous quantification of DQ, PQ, GLU, and GLYP in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS) without using derivatization or ion-pairing reagents. DQ, PQ, GLU, and GLYP were extracted by the rapid protein precipitation and liquid-liquid extraction method and then separated and detected by LC-MS/MS. Subsequently, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, extraction recovery, matrix effect, dilution integrity, and stability were evaluated to validate the method based on the FDA criteria. Finally, the validated method was applied to real plasma samples collected from 166 Chinese patients with herbicide poisoning. The results showed satisfactory linearity with low LOD (1 ng/mL for DQ and PQ, 5 ng/mL for GLU, and 10 ng/mL for GLYP, respectively) and low LOQ (5 ng/mL for DQ and PQ, 25 ng/mL for GLU and GLYP, respectively). In addition, the precision, accuracy, extraction recovery, and stability of the method were acceptable. The matrix effect was not observed in the analyzed samples. Moreover, the developed method was successfully applied to determine the target compounds in real plasma samples. These data provided reliable evidence for the application of this LC-MS/MS method for clinical poisoning detection.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Paraquat / Diquat / Espectrometria de Massas em Tandem / Limite de Detecção / Glifosato / Glicina / Aminobutiratos / Herbicidas Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Paraquat / Diquat / Espectrometria de Massas em Tandem / Limite de Detecção / Glifosato / Glicina / Aminobutiratos / Herbicidas Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article