Improving hybrid image and structure-based deformable image registration for large internal deformations.
Phys Med Biol
; 69(9)2024 Apr 17.
Article
em En
| MEDLINE
| ID: mdl-38518382
ABSTRACT
Objective.Deformable image registration (DIR) is a widely used technique in radiotherapy. Complex deformations, resulting from large anatomical changes, are a regular challenge. DIR algorithms generally seek a balance between capturing large deformations and preserving a smooth deformation vector field (DVF). We propose a novel structure-based term that can enhance the registration efficacy while ensuring a smooth DVF.Approach.The proposed novel similarity metric for controlling structures was introduced as a new term into a commercially available algorithm. Its performance was compared to the original algorithm using a dataset of 46 patients who received pelvic re-irradiation, many of which exhibited complex deformations.Main results.The mean Dice Similarity Coefficient (DSC) under the improved algorithm was 0.96, 0.94, 0.76, and 0.91 for bladder, rectum, colon, and bone respectively, compared to 0.69, 0.89, 0.62, and 0.88 for the original algorithm. The improvement was more pronounced for complex deformations.Significance.With this work, we have demonstrated that the proposed term is able to improve registration accuracy for complex cases while maintaining realistic deformations.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Processamento de Imagem Assistida por Computador
/
Tomografia Computadorizada por Raios X
Limite:
Humans
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article