Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation.
Ait Ali, Lamia; Martini, Nicola; Listo, Elisa; Valenti, Elisa; Sotelo, Julio; Salvadori, Stefano; Passino, Claudio; Monteleone, Angelo; Stagnaro, Nicola; Trocchio, Gianluca; Marrone, Chiara; Raimondi, Francesca; Catapano, Giosuè; Festa, Pierluigi.
Afiliação
  • Ait Ali L; Institute of Clinical Physiology, National Research Council, Via Aurelia Sud, 54100, Massa, Pisa, Italy. aitlamia@ifc.cnr.it.
  • Martini N; Gabriele Monasterio Foundation, Pisa, Massa, Italy. aitlamia@ifc.cnr.it.
  • Listo E; Gabriele Monasterio Foundation, Pisa, Massa, Italy.
  • Valenti E; Azienda Ospedaliera ASL, 3-Ospedale Villascassi, Genoa, Italy.
  • Sotelo J; Institute of Clinical Physiology, National Research Council, Via Aurelia Sud, 54100, Massa, Pisa, Italy.
  • Salvadori S; Departamento de Informática, Universidad Técnica Federico Santa María, Santiago, Chile.
  • Passino C; Institute of Clinical Physiology, National Research Council, Via Aurelia Sud, 54100, Massa, Pisa, Italy.
  • Monteleone A; Gabriele Monasterio Foundation, Pisa, Massa, Italy.
  • Stagnaro N; Gabriele Monasterio Foundation, Pisa, Massa, Italy.
  • Trocchio G; IRCCS Istituto Giannina Gaslini, Genoa, Italy.
  • Marrone C; ASST Ospedale Papa Giovanni XXIII, Piazza OMS, 1, 24127, Bergamo BG, Bergamo, Italy.
  • Raimondi F; Gabriele Monasterio Foundation, Pisa, Massa, Italy.
  • Catapano G; ASST Ospedale Papa Giovanni XXIII, Piazza OMS, 1, 24127, Bergamo BG, Bergamo, Italy. francesca.raimondi@gmail.com.
  • Festa P; Gabriele Monasterio Foundation, Pisa, Massa, Italy.
Pediatr Cardiol ; 45(5): 998-1006, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38519622
ABSTRACT
We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients' post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m2, p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO2/kg/min R - 0.45, p = 0.01 peak, minute ventilation (VE) R - 0.466, p < 0.01, maximal voluntary ventilation R0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak R 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.