Your browser doesn't support javascript.
loading
Lipid Wizard: Analysis Software for Comprehensive Two-Dimensional Liquid Chromatography-Mass Spectrometry-Based Lipid Profiling.
Xu, Raobo; Liu, Huan; Yuan, Fang; Kim, Seongho; Kirpich, Irina; McClain, Craig J; Zhang, Xiang.
Afiliação
  • Xu R; Department of Chemistry, University of Louisville, Louisville, Kentucky 40292, United States.
  • Liu H; Alcohol Research Center, University of Louisville, Louisville, Kentucky 40292, United States.
  • Yuan F; Hepatobiology and Toxicology Center of Biomedical Research Excellence, University of Louisville, Louisville, Kentucky 40292, United States.
  • Kim S; Center for Regulatory and Environmental Analytical Metabolomics, University of Louisville, Louisville, Kentucky 40292, United States.
  • Kirpich I; Department of Computer Science and Engineering, University of Louisville, Louisville, Kentucky 40292, United States.
  • McClain CJ; Department of Chemistry, University of Louisville, Louisville, Kentucky 40292, United States.
  • Zhang X; Alcohol Research Center, University of Louisville, Louisville, Kentucky 40292, United States.
Anal Chem ; 96(14): 5375-5383, 2024 Apr 09.
Article em En | MEDLINE | ID: mdl-38523323
ABSTRACT
Lipids play a significant role in life activities and participate in the biological system through different pathways. Although comprehensive two-dimensional liquid chromatography-mass spectrometry (2DLC-MS) has been developed to profile lipid abundance changes, lipid identification and quantification from 2DLC-MS data remain a challenge. We created Lipid Wizard, open-source software for lipid assignment and isotopic peak stripping of the 2DLC-MS data. Lipid Wizard takes the peak list deconvoluted from the 2DLC-MS data as input and assigns each isotopic peak to the lipids recorded in the LIPID MAPS database by precursor ion m/z matching. The matched lipids are then filtered by the first-dimension retention time (1D RT), followed by the second-dimension retention time (2D RT), where the 2D RT of each lipid is predicted using an equivalent carbon number (ECN) model. The remaining assigned lipids are used for isotopic peak stripping via an iterative linear regression. The performance of Lipid Wizard was tested using a set of lipid standards and then applied to study the lipid changes in the livers of mice (fat-1) fed with alcohol.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massa com Cromatografia Líquida / Lipídeos Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article