Your browser doesn't support javascript.
loading
Dense Multibutterfly Spots-Enhanced Miniaturized Optical Fiber Photoacoustic Gas Sensor.
Zhao, Xinyu; Qi, Hongchao; Wang, Heng; Wang, Xiaona; Guo, Min; Peng, Wei; Chen, Ke.
Afiliação
  • Zhao X; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Qi H; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Wang H; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Wang X; School of Physics, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Guo M; Zhejiang Engineering Research Center of MEMS, Shaoxing University, Shaoxing, Zhejiang 312000, China.
  • Peng W; School of Physics, Dalian University of Technology, Dalian, Liaoning 116024, China.
  • Chen K; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
Anal Chem ; 96(14): 5554-5559, 2024 Apr 09.
Article em En | MEDLINE | ID: mdl-38545859
ABSTRACT
A miniaturized optical fiber photoacoustic gas sensor enhanced by dense multibutterfly spots is reported for the first time. The principle of space light transmission of neglecting paraxial approximation is theoretically analyzed for designing a dense multibutterfly spots-based miniature multipass cell. In a multipass photoacoustic tube with a diameter of 16 mm, the light beam is reflected about a hundred times. The light spots on the mirror surfaces at both ends of the photoacoustic tube form a dense multibutterfly distribution. The volume of the micro multipass gas chamber is only 5.3 mL. An optical fiber cantilever based on F-P interference is utilized as a photoacoustic pressure detector. Compared with that of the single-pass structure, the gas detection ability of the photoacoustic system with dense multibutterfly spots is improved by about 50 times. The proposed miniaturized sensor realizes a detection limit of 3.4 ppb for C2H2 gas with an averaging time of 100 s. The recognized coefficients of minimum detectable absorption (αmin) and normalized noise equivalent absorption are 1.9 × 10-8 cm-1 and 8.4 × 10-10 W cm-1 Hz-1/2, respectively.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article