Comparative diagnostic accuracy of transcranial Doppler and contrast-enhanced transthoracic echocardiography for the diagnosis of patent foramen ovale and atrial septal defect.
Lanzone, Alberto M; Castelluccio, Emanuele V; Della Pina, Paolo; Boldi, Emiliano; Lussardi, Gianluca; Frati, Giacomo; Gaudio, Carlo; Biondi-Zoccai, Giuseppe.
Afiliação
  • Lanzone AM; Division of Cardiology and Coronary Care Unit, San Rocco Clinical Institute, Ome, Brescia, Italy.
  • Castelluccio EV; Department of Health Promotion, Mother and Child Care, G. D'Alessandro Internal Medicine and Medical Specialties (PROMISE), University of Palermo, Palermo, Italy.
  • Della Pina P; Division of Cardiology, Paolo Giaccone University Hospital, Palermo, Italy.
  • Boldi E; Division of Cardiology and Coronary Care Unit, San Rocco Clinical Institute, Ome, Brescia, Italy.
  • Lussardi G; Division of Cardiology and Coronary Care Unit, San Rocco Clinical Institute, Ome, Brescia, Italy.
  • Frati G; Department of Vascular Surgery, Spedali Civili, Brescia, Italy.
  • Gaudio C; Department of Medical-Surgical Sciences and Biotechnologies, Sapienza University, Latina, Italy.
  • Biondi-Zoccai G; IRCCS Neuromed, Pozzilli, Isernia, Italy.
Panminerva Med ; 66(2): 124-130, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38563605
ABSTRACT

BACKGROUND:

Recognition of right-to-left shunt is crucial in the work-up of patients with suspected patent foramen ovale (PFO) or atrial septal defect (ASD). While transesophageal echocardiography (TEE) remains the gold standard diagnostic tool for the anatomic assessment of PFO/ASD, transcranial Doppler (TCD) and contrast-enhanced transthoracic echocardiogram (CE-TTE) hold the promise of providing minimally invasive yet accurate clinical details. Their comparative accuracy remains however debated.

METHODS:

We conducted a retrospective observational study leveraging our extensive institutional experience with systematic TCD and CE-TTE in patients with suspected PFO/ASD. Several measures of diagnostic test accuracy were computed, with point estimates and 95% confidence intervals, when applicable.

RESULTS:

A total of 1358 patients were included, with age 48±14 years and 772 (58%) women. Tests were performed for diagnostic purposes in 797 (58.6%) and during follow-up in 740 (54.5%). A PFO was eventually diagnosed in 1038 (77.9%) patients, and an ASD in 60 (4.5%). Agreement between TCD and CE-TTE occurred in 1309 (85.2%) cases, with TCD yielding worse findings than CE-TTE in 91 (5.9%) patients, and vice versa in 137 (8.9%), yielding a Cohen kappa of 78.6% (95% CI 76.3-81.1%) and a highly significant P value at McNemar test (P<0.001). After dichotomization, and using TCD as benchmark, CE-TTE yielded sensitivity 96.9%, specificity 95.1%, area under the curve 92.1%, and P=0.249. Similar findings were obtained when focusing only on diagnostic tests or follow-up ones (Cohen kappa respectively 74.0% [70.2-77.1%], P<0.001 and 80.3% [76.4-84.3%], P<0.001). Notably, Valsalva was necessary to disclose the presence of shunt during TCD in 487 (31.7%) patients and during CE-TTE in 482 (31.4%) cases. Finally, performance of TCD and CE-TTE in a subset of patients eventually undergoing TTE was quite similar.

CONCLUSIONS:

The diagnostic accuracy of CE-TTE appears favorable, and this imaging test may identify patients who may be missed if only TCD is used to screen patients with suspected PFO/ASD. Accordingly, CE-TTE is recommended as an adjunct diagnostic modality for all patients with a high pre-test probability of PFO/ASD and right-to-left shunt.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ecocardiografia / Ultrassonografia Doppler Transcraniana / Meios de Contraste / Forame Oval Patente / Comunicação Interatrial Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ecocardiografia / Ultrassonografia Doppler Transcraniana / Meios de Contraste / Forame Oval Patente / Comunicação Interatrial Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article