Your browser doesn't support javascript.
loading
Evaluation of visual outcomes with toric intraocular lens implantation using digital marker during cataract surgery.
Jeeva, Irfan Kabiruddin; Masud, Sidra; Ali, Tazeen Saeed; Siddiqui, Muhammad Abdul Rehman; Waheed, Ayesha Akbar; Awan, Amna.
Afiliação
  • Jeeva IK; Department of Ophthalmology and Visual Sciences, Aga Khan University Hospital, Karachi, Pakistan.
  • Masud S; Department of Ophthalmology and Visual Sciences, Aga Khan University Hospital, Karachi, Pakistan.
  • Ali TS; Department of Community Health Sciences, Aga Khan University Hospital, Karachi, Pakistan.
  • Siddiqui MAR; Department of Ophthalmology and Visual Sciences, Aga Khan University Hospital, Karachi, Pakistan.
  • Waheed AA; 5th Year MBBS Student, Aga Khan University, Karachi, Pakistan.
  • Awan A; 4th Year MBBS Student, Ziauddin Medical University, Karachi, Pakistan.
J Pak Med Assoc ; 74(3): 450-455, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38591276
ABSTRACT

Objectives:

To assess the visual improvement and mean residual astigmatism in patients who underwent cataract surgery with toric intraocular lens.

METHODS:

The retrospective, observational study was conducted at the Department of Ophthalmology, Aga Khan University Hospital, Karachi, and comprised data from January 1, 2018, to December 31, 2020, related to adult patients who had regular astigmatism of at least 0.75D and underwent cataract surgery with toric intraocular lens implantation using a digital marker. The patients were followed up on post-operative days 1, 7, 30, 90 and 180. Along with age, the degree of astigmatism was noted. The visual acuity was calculated pre- and post-operatively. The mean residual astigmatism was then noted for all patients post-operatively. Data was analysed using SPSS 22.

RESULTS:

The sample comprised 240 eyes of 177 patients; 99(55.9%) males and 78(44.1%) females. The mean age of the sample was 62.5±10.6 years. The mean unaided visual acuity improved post-operatively from 0.57±0.38 to 0.07±0.22 at 90 days. At the 30-day follow-up, mean residual astigmatism had reduced from 1.52±0.84 to 0.01±0.09 (p<0.001). The mean intraocular lens rotation from the intended axis was 0.73°±0.92° on day 30.

CONCLUSIONS:

Toric intraocular lens implantation using a digital marker could effectively reduce the post-operative cylinder, and improve the unaided visual acuity following cataract surgery.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Astigmatismo / Catarata / Facoemulsificação / Lentes Intraoculares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Astigmatismo / Catarata / Facoemulsificação / Lentes Intraoculares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article