Your browser doesn't support javascript.
loading
Perceval-S over time. Clinical outcomes after ten years of usage.
Schizas, Nikolaos; Samiotis, Ilias; Nazou, Georgia; Iliopoulos, Dimitrios C; Anagnostopoulos, Ioannis; Kousta, Maria; Papaioannou, Nafsika; Argiriou, Mihalis; Dedeilias, Panagiotis.
Afiliação
  • Schizas N; Cardiovascular and Thoracic Surgery Department, Evangelismos General Hospital, Athens, Greece. nikschizas@gmail.com.
  • Samiotis I; Cardiovascular and Thoracic Surgery Department, Evangelismos General Hospital, Athens, Greece.
  • Nazou G; Department of Anesthesiology, Evangelismos General Hospital, Athens, Greece.
  • Iliopoulos DC; National and Kapodistrian University of Athens, Athens, Greece.
  • Anagnostopoulos I; Department of Cardiology, G. Gennimatas General Hospital, Athens, Greece.
  • Kousta M; Department of Cardiology, G. Gennimatas General Hospital, Athens, Greece.
  • Papaioannou N; Environmental Engineering Laboratory, Aristotle University, Thessaloniki, Greece.
  • Argiriou M; Cardiovascular and Thoracic Surgery Department, Evangelismos General Hospital, Athens, Greece.
  • Dedeilias P; Cardiovascular and Thoracic Surgery Department, Evangelismos General Hospital, Athens, Greece.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Article em En | MEDLINE | ID: mdl-38594705
ABSTRACT

BACKGROUND:

Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND

METHODS:

This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020.

RESULTS:

The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected.

CONCLUSIONS:

The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Bioprótese / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca Limite: Aged / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Bioprótese / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca Limite: Aged / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article