Your browser doesn't support javascript.
loading
A Wearable Sandwich Heterostructure Multimode Fiber Optic Microbend Sensor for Vital Signal Monitoring.
Zhou, Fumin; Luo, Binbin; Zou, Xue; Zou, Chaoke; Wu, Decao; Wang, Zhijun; Bai, Yunfang; Zhao, Mingfu.
Afiliação
  • Zhou F; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
  • Luo B; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
  • Zou X; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
  • Zou C; School of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
  • Wu D; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
  • Wang Z; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
  • Bai Y; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
  • Zhao M; Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China.
Sensors (Basel) ; 24(7)2024 Mar 29.
Article em En | MEDLINE | ID: mdl-38610420
ABSTRACT
This work proposes a highly sensitive sandwich heterostructure multimode optical fiber microbend sensor for heart rate (HR), respiratory rate (RR), and ballistocardiography (BCG) monitoring, which is fabricated by combining a sandwich heterostructure multimode fiber Mach-Zehnder interferometer (SHMF-MZI) with a microbend deformer. The parameters of the SHMF-MZI sensor and the microbend deformer were analyzed and optimized in detail, and then the new encapsulated method of the wearable device was put forward. The proposed wearable sensor could greatly enhance the response to the HR signal. The performances for HR, RR, and BCG monitoring were as good as those of the medically approved commercial monitors. The sensor has the advantages of high sensitivity, easy fabrication, and good stability, providing the potential for application in the field of daily supervision and health monitoring.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article