Your browser doesn't support javascript.
loading
Comparison of preoxygenation using a tight facemask, humidified high-flow nasal oxygen and a standard nasal cannula - a volunteer, randomised, crossover study.
Sjöblom, Albin; Hedberg, Magnus; Forsberg, Ida-Maria; Hoffman, Frida; Jonsson Fagerlund, Malin.
Afiliação
  • Sjöblom A; From the Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden (AS, MH, I-MF, FH, MJF), Department of Physiology and Pharmacology, Section for Anesthesiology and Intensive Care Medicine, Karolinska Institutet, Stockholm, Sweden (AS, MH, I-MF, FH, MJF).
Eur J Anaesthesiol ; 41(6): 430-437, 2024 Jun 01.
Article em En | MEDLINE | ID: mdl-38630525
ABSTRACT

BACKGROUND:

Preoxygenation before anaesthesia induction is routinely performed via a tight-fitting facemask or humidified high-flow nasal oxygen. We hypothesised that effective preoxygenation, assessed by end-tidal oxygen (EtO 2 ) levels, can also be performed via a standard nasal cannula.

OBJECTIVE:

This study compared the efficacy of preoxygenation between a traditional facemask, humidified high-flow nasal oxygen and a standard nasal cannula.

DESIGN:

A volunteer, randomised, crossover study.

SETTING:

Karolinska University Hospital, Stockholm. The study was conducted between 2 May and 31 May 2023.

PARTICIPANTS:

Twenty cardiopulmonary healthy volunteers aged 25-65 years with a BMI <30.

INTERVENTIONS:

Preoxygenation using a traditional facemask, humidified high-flow nasal oxygen and standard nasal cannula. Volunteers were preoxygenated with all three methods, at various flow rates (10-50 l min -1 ), with open and closed mouths and during vital capacity manoeuvres. MAIN OUTCOME

MEASURES:

The study's primary outcome compared the efficacy after 3 min of preoxygenation, assessed by EtO 2 levels, between the three methods and various flow rates of preoxygenation.

RESULTS:

Three methods generated higher EtO 2 levels than others (i) facemask preoxygenation using normal breathing, (ii) humidified high-flow nasal oxygen, closed-mouth breathing, at 50 l min -1 and (iii) standard nasal cannula, closed-mouth breathing, at 50 l min -1 , and expressed as means (SD) 90% (3), 90% (6) and 88% (5), respectively. Preoxygenation efficacy was greater via the bi-nasal cannulae using closed vs. open mouth breathing as well as with 3 min of normal breathing vs. eight vital capacity breaths. Preoxygenation with a facemask and humidified high-flow nasal oxygen was more comfortable than a standard nasal cannula.

CONCLUSION:

The efficacy of preoxygenation using a standard nasal cannula at high flow rates is no different to clinically used methods today. The standard nasal cannula provides less comfort but is highly effective and could be an option when alternative methods are unavailable. TRIAL REGISTRATION Clinicaltrials.gov, NCT05839665.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Oxigenoterapia / Estudos Cross-Over / Cânula / Máscaras Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Oxigenoterapia / Estudos Cross-Over / Cânula / Máscaras Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article