Novel EDTA mediated ethanol protein precipitation method and the application for polysorbate quantification in high protein concentration biopharmaceuticals.
Halim, Vincentius A; de Jonker, Maurice; Esteve, Clara; Assenberg, Rene; Balog, Crina.
Afiliação
  • Halim VA; Therapeutics Development and Supply, Analytical Development, Janssen Biologics BV., Einsteinweg 101, Leiden 2333 CB, the Netherlands. Electronic address: vhalim@its.jnj.com.
  • de Jonker M; Therapeutics Development and Supply, Analytical Development, Janssen Biologics BV., Einsteinweg 101, Leiden 2333 CB, the Netherlands.
  • Esteve C; Therapeutics Development and Supply, Analytical Development, Janssen Biologics BV., Einsteinweg 101, Leiden 2333 CB, the Netherlands.
  • Assenberg R; Therapeutics Development and Supply, Analytical Development, Janssen Biologics BV., Einsteinweg 101, Leiden 2333 CB, the Netherlands.
  • Balog C; Therapeutics Development and Supply, Analytical Development, Janssen Biologics BV., Einsteinweg 101, Leiden 2333 CB, the Netherlands; Manufacturing Science and Technology, Janssen Biologics BV., Einsteinweg 101, Leiden 2333 CB, the Netherlands.
J Pharm Biomed Anal ; 245: 116145, 2024 Aug 01.
Article em En | MEDLINE | ID: mdl-38631071
ABSTRACT
Non-ionic surfactants such as Polysorbate 20/ 80 (PS20/ PS80), are commonly used in protein drug formulations to increase protein stability by protecting against interfacial stress and surface absorption. Polysorbate is susceptible to degradation which can impact product stability, leading to the formation of sub-visible and/or visible particles in the drug product during its shelf-life, affecting patient safety and efficacy. Therefore, it is important to monitor polysorbate concentration in drug product formulations of biotherapeutic drugs. The common method for measuring polysorbate concentration in drug product formulations uses mixed mode ion exchange reversed phase HPLC (MAX) coupled to evaporative light scattering detection (ELSD). However, high protein concentration can adversely impact method performance due to high sample viscosity, gel formation, column clogging, interfering peaks and loss of accuracy. To overcome this, a new method was developed based on EDTA mediated ethanol protein precipitation (EDTA/EtOH). This method was successfully implemented for the analysis of polysorbate in antibody formulations with wide range of protein concentration (10-250 mg/mL).