Your browser doesn't support javascript.
loading
Combined transcatheter aortic valve and tricuspid valve-in-valve implantation in a patient with a mitral mechanical prosthesis.
Lima, Maria Rita; Brito, João; Almeida, Manuel; Teles, Rui Campante.
Afiliação
  • Lima MR; Cardiology Department, Hospital de Santa Cruz, Centro Hospitalar de Lisboa Ocidental, Lisbon, Portugal.
  • Brito J; Cardiology Department, Hospital de Santa Cruz, Centro Hospitalar de Lisboa Ocidental, Lisbon, Portugal.
  • Almeida M; Cardiovascular Intervention Unit, Hospital de Santa Cruz, Centro Hospitalar de Lisboa Ocidental, Lisbon, Portugal.
  • Teles RC; Cardiology Department, Hospital de Santa Cruz, Centro Hospitalar de Lisboa Ocidental, Lisbon, Portugal.
Catheter Cardiovasc Interv ; 103(7): 1159-1164, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38639138
ABSTRACT
Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Desenho de Prótese / Cardiopatia Reumática / Valva Tricúspide / Bioprótese / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca / Substituição da Valva Aórtica Transcateter / Valva Mitral Limite: Aged80 / Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Desenho de Prótese / Cardiopatia Reumática / Valva Tricúspide / Bioprótese / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca / Substituição da Valva Aórtica Transcateter / Valva Mitral Limite: Aged80 / Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article