BACKGROUND:
Carotid duplex ultrasonography (DUS) is the primary screening tool for carotid artery stenosis, but has low reliability. MHR, which is the ratio of monocytes to high-density lipoprotein cholesterol (HDL-C), can be a marker for the degree and distribution of extracranial and intracranial atherosclerotic stenosis.OBJECTIVE:
We determined the diagnostic value of DUS+MHR for internal carotid artery (ICA) stenosis.METHODS:
We divided 273 hospitalized patients into non-stenosis (<50%) and ICA stenosis (≥50%) groups based on Digital Subtraction Angiography (DSA). We determined the peak systolic velocity (PSV) in the ICA on DUS, calculated the MHR, and investigated their relationship with ICA stenosis.RESULTS:
On DSA, 34.1% (93/273) patients had moderate-to-severe ICA stenosis. DUS and DSA showed low concordance for detecting ICA stenosis (kappa = 0.390). With increasing age, the incidence of moderate-to-severe ICA stenosis increased. PSV, monocyte count, and MHR were significantly greater in the stenosis group than in the non-stenosis group (P < 0.001), while the HDL-C level was significantly lower (P = 0.001). PSV (OR 1.020, 95% CI 1.011-1.029, P < 0.001) and MHR (OR 5.662, 95% CI 1.945-16.482, P = 0.002) were independent risk factors for ICA stenosis. The area under the receiver operating characteristic curve of PSV+MHR (0.819) was significantly higher than that of PSV or MHR alone (77.42% sensitivity, P = 0.0207; 73.89% specificity, P = 0.0032).CONCLUSION:
The combination of ICA PSV on DUS and MHR is better than PSV alone at identifying ICA stenosis and is well-suited to screen high-risk patients.