Your browser doesn't support javascript.
loading
A Pilot Study of Aerosolization of Infectious Murine Norovirus in an Experimental Setup.
Purhonen, Roderik; Atanasova, Nina S; Salokas, Julija; Duplissy, Jonathan; Loikkanen, Emil; Maunula, Leena.
Afiliação
  • Purhonen R; Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
  • Atanasova NS; Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Helsinki, Finland.
  • Salokas J; Atmospheric Composition Unit, Finnish Meteorological Institute, Helsinki, Finland.
  • Duplissy J; Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.
  • Loikkanen E; Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Helsinki, Finland.
  • Maunula L; Institute for Atmospheric and Earth System Research (INAR), Faculty of Science, University of Helsinki, Helsinki, Finland.
Food Environ Virol ; 2024 May 02.
Article em En | MEDLINE | ID: mdl-38698288
ABSTRACT
Human norovirus is transmitted mainly via the faecal-oral route, but norovirus disease outbreaks have been reported in which airborne transmission has been suggested as the only explanation. We used murine norovirus (MNV) as a surrogate for human norovirus to determine the aerosolization of infectious norovirus in an experimental setup. A 3-l air chamber system was used for aerosolization of MNV. Virus in solution (6 log10 TCID50/ml) was introduced into the nebulizer for generating aerosols and a RAW 264.7 cell dish without a lid was placed in the air chamber. Cell culture medium samples were taken from the dishes after the aerosol exposure time of 30 or 90 min, and the dishes were placed in a 37 °C, 5% CO2 incubator and inspected with a light microscope for viral cytopathic effects (CPEs). We determined both the infectious MNV TCID50 titre and used an RT-qPCR assay. During the experiments, virus infectivity remained stable for 30 and 90 min in the MNV solution in the nebulizer. Infectious MNV TCID50 values/ml of 2.89 ± 0.29 and 3.20 ± 0.49 log10 were measured in the chamber in RAW 264.7 cell dish media after the 30-min and 90-min exposure, respectively. The MNV RNA loads were 6.20 ± 0.24 and 6.93 ± 1.02 log10 genome copies/ml, respectively. Later, a typical MNV CPE appeared in the aerosol-exposed RAW cell dishes. We demonstrated that MNV was aerosolized and that it remained infectious in the experimental setup used. Further studies required for understanding the behaviour of MNV in aerosols can thus be performed.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article