Relative biological effectiveness of oxygen ion beams in the rat spinal cord: Dependence on linear energy transfer and dose and comparison with model predictions.
Glowa, Christin; Saager, Maria; Hintz, Lisa; Euler-Lange, Rosemarie; Peschke, Peter; Brons, Stephan; Scholz, Michael; Mein, Stewart; Mairani, Andrea; Karger, Christian P.
Afiliação
  • Glowa C; Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Saager M; National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.
  • Hintz L; Department of Radiation Oncology and Radiotherapy, University Hospital Heidelberg, Germany.
  • Euler-Lange R; Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Peschke P; National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.
  • Brons S; Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Scholz M; National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.
  • Mein S; Faculty of Biosciences, Heidelberg University, Heidelberg, Germany.
  • Mairani A; Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Karger CP; National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.
Phys Imaging Radiat Oncol ; 30: 100581, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38711920
ABSTRACT
Background and

purpose:

Ion beams exhibit an increased relative biological effectiveness (RBE) with respect to photons. This study determined the RBE of oxygen ion beams as a function of linear energy transfer (LET) and dose in the rat spinal cord. Materials and

methods:

The spinal cord of rats was irradiated at four different positions of a 6 cm spread-out Bragg-peak (LET 26, 66, 98 and 141 keV/µm) using increasing levels of single and split oxygen ion doses. Dose-response curves were established for the endpoint paresis grade II and based on ED50 (dose at 50 % effect probability), the RBE was determined and compared to model predictions.

Results:

When LET increased from 26 to 98 keV/µm, ED50 decreased from 17.2 ± 0.3 Gy to 13.5 ± 0.4 Gy for single and from 21.7 ± 0.4 Gy to 15.5 ± 0.5 Gy for split doses, however, at 141 keV/µm, ED50 rose again to 15.8 ± 0.4 Gy and 17.2 ± 0.4 Gy, respectively. As a result, the RBE increased from 1.43 ± 0.05 to 1.82 ± 0.08 (single dose) and from 1.58 ± 0.04 to 2.21 ± 0.08 (split dose), respectively, before declining again to 1.56 ± 0.06 for single and 1.99 ± 0.06 for split doses at the highest LET. Deviations from RBE-predictions were model-dependent.

Conclusion:

This study established first RBE data for the late reacting central nervous system after single and split doses of oxygen ions. The data was used to validate the RBE-dependence on LET and dose of three RBE-models. This study extends the existing data base for protons, helium and carbon ions and provides important information for future patient treatments with oxygen ions.